Reaction times on FlexRay and CAN:
measured under Windows 2000 SP4 or Windows XP SP2, AMD Athlon processor with 1
GHz.
Time difference on the PC:
from the moment of transmission of a message to the FlexRay bus
to the moment of reception of the echo (echo after 5 ms) from the FlexRay bus
Minimum
Average
Maximum
15 ms
19 ms
26 ms
Time difference on the PC:
from the moment of transmission of a message to the CAN bus
to the moment of reception of the echo (instantaneous echo) from the CAN bus
Minimum
Average
Maximum
1 ms
1 ms
2 ms
Ordering codes
The following options are available:
Description
Article no.
FlexRay CCM
1.01.0100.00011
FlexRay CCM Dual Chip
1.01.0100.00014
FlexRay CCM-E (blues, stackable housing)
1.01.0100.00016
FlexRay Dual Chip Upgradekit
1.01.0101.00012
FRC-EP150
1.01.0102.00011
FRC-EP150 Dual Chip
1.01.0102.00014