![IXXAT CAN@net II/Generic Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/ixxat/canatnet-ii-generic/canatnet-ii-generic_manual_2098901039.webp)
CAN@net II/Generic, Version 1.5
ASCII Protocol Short Reference
39
D Command
Info Message (response to device command)
D VER
I CAN_at_net_II_ZZ_YY, FW V2.01.02, HW V1.4,
SerNo HWxxxxxx
D PROTO
I ASCII Extended Protocol V1.1
D CONFIG SAVE
I OK (CAN config saved to flash)
D RESET
I Resetting device ...
Bridge Mode
Info Message
Heartbeat message I HEARTBEAT X
Note: X is a 32 bit hexadecimal value of the up time in
seconds
Heartbeat timeout
I Heartbeat timed out. Resetting device ...
Error Messages
No. Description
E 10 Software queue overrun
E 11 CAN controller buffer overrun
E 12 CAN error status set
E 13 CAN error status reset
E 14 Bus off
E 20 Unknown message frame format
E 21 Unknown message RTR flag
E 70 Device rejected incoming connection because it is already connected
E 75 ID 0xX not found in the filter list
E 76 ID 0xX is already in the filter list
E 77 ID 0xX was not added to the list, filter list full
E 80
Unknown command
Unknown device command
Wrong parameter
Wrong config parameter
Wrong init parameter
Wrong filter parameter
E 81 CAN init command received. Baudrate [XYZ] is unknown
E 82 CAN bus baud rate was not detected
CAN init command received. Could not detect baudrate. AutoBaud
failed.