Wiring Diagrams
Fig. 5: Wiring diagram.
IXL Eco Ventflo
Installation
Important considerations before installing
• Joists, beams and rafters shall not be cut or notched to install the appliance.
• This unit has an IPX4 rating which means it is suitable for Zone 1 installations and can be installed
directly above a shower or bath.
• For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn under the door or
through a slightly open window. If the room is airtight the fan will function poorly.
• This product is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling
or vertical wall.
Fig. 7: Mounting clips open
Fig. 6: Mounting clips closed
IXL Eco Ventflo
1. Locating the unit – Before commencing any
cutting, check in the ceiling space that there are
no obstructions such as ceiling joists and that
there is sufficient clearance for the housing.
Check that the electrical wiring can be routed from
the wall switches to the mounting location.
2. Prepare the ceiling – Using the template provided
on page 15, mark the ceiling with a pencil outline
and cut out the required hole (10324 needs 244
mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plug the fan into the power point.
5. Ensure that the mounting clips are in the closed
position, then insert fan into ceiling cut out.
6. Using a screwdriver (or a battery driver with a low
torque setting) partially tighten the screws.
This will move the mounting clips into the open
position and hold the unit to the ceiling.
7. Rotate the unit so that the grille direction
lines on the body are aligned with the walls.
These lines show the orientation of the fascia
grille when installed.
8. Tighten the screws. Do not over tighten as this
can damage plasterboard.
9. Fit grille onto unit. Once fitted the grille can be
adjusted to better align with the walls.
8
10324
: 0.13A 50Hz,
10326
: 0.25A 50Hz