IXL 10324 Скачать руководство пользователя страница 2

Welcome

Thank you for buying this IXL Eco Ventflo Fan. Even if you have used an exhaust fan before, there are 

some very good reasons to read this user guide before using this one:
•  You and your family, property and home will be safe from harm.
•  You will learn how this appliance may differ from others.
•  By using the Ventflo Fan fully and properly, you will get maximum life and value from it.
•   Our warranty depends on you using the Ventflo Fan according to this user guide.
It will only take you a few minutes, so please read on! 

Contents

Safety

 ............................................................................

Pg 3-4

Ventilation Requirements

 ................................................

Pg 5

Clearances

 .......................................................................

Pg 6

Flat Roof Installations

 .....................................................

Pg 7

Electrical Requirements

 ..................................................

Pg 7

Wiring Diagrams

 ..............................................................

Pg 8

Installation

 .......................................................................

Pg 9

Use

..................................................................................

Pg 10

Cleaning

 .........................................................................

Pg 10

Record Your Model

 ........................................................

Pg 11

Warranty

 ...................................................................

Pg 12-13

Notes .............................................................................. Pg 14
Template for Cut Out ...................................................... Pg 15

Safety

IXL Eco Ventflo

Read through these instructions fully before commencing installation.
Locate the IXL Eco Ventflo in accordance with the requirements of the current Australian/ New Zealand 

Wiring Rules AS/NZS 3000 relating to damp situations, or according to applicable Wiring Rules for 

installations outside of Australia and New Zealand. This appliance has an IPX4 rating which means it is 

suitable for Zone 1 installations and can be mounted directly above a bath or shower recess.
This unit is fitted with a cord and plug, however, any interconnecting wiring and switches used must 

be fitted by a licensed electrician.
Switches and other controls must not be located where they can be touched by a person in the bath  

or shower.

Warning

:

•  Do not use this appliance for functions other than those described in this user guide.
•  After removing the appliance from its packaging, ensure that it is complete and undamaged.  

If in doubt contact a qualified electrician or Sampford IXL. Do not leave packaging within the reach 

of children or infirm persons.

•  This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been  

given supervision or instruction concerning the use of the appliance by a person responsible for 

their safety.

•  Young children should be supervised to ensure they do not play with the appliance.
•  Do not operate the appliance in the presence of inflammable vapours  

(alcohol, insecticides, petrol, etc.)

•  Do not sit or place objects on or in the appliance.
•  The supply cord cannot be replaced.  If the cord is damaged the appliance should be scrapped.
•  Do not operate this appliance without the plastic surround in position.
•  This appliance must be mounted with the lowest point at least 2.1 metres from the floor.

Caution

:

•  Do not make modifications of any kind to this appliance.
•  Do not expose this appliance to the weather (rain, sun, etc.)
•  Do not immerse the appliance or any parts of it in water or other liquids. Refer to the relevant 

instructions to clean the appliance (page 10)

Do not allow insulation material to rest against the sides or  

top of the Ventflo unit when installed.

2

Содержание 10324

Страница 1: ...User Guide IXL Eco Ventflo Model 10324 200mm Extraction Rate 340m3 h Model 10326 250mm Extraction Rate 490m3 h Electrical Rating 230 240 V 50 Hz...

Страница 2: ...y a licensed electrician Switches and other controls must not be located where they can be touched by a person in the bath or shower Warning Do not use this appliance for functions other than those de...

Страница 3: ...cated on the back of this booklet For further details and advice on ventilation products and tips visit the IXL Ventilation Selection Guide on our website www sampfordixl com au 4 If the appliance doe...

Страница 4: ...2 DRN 3 4 5 6 7 8 9 10 11 12 g MASS VENTFLO 200 AXIAL FAN VOLUME mm3 Fig 2 Adequate open space in the roof cavity is required A B FLAPS DRN CHK APP REL 3rd ANGLE PROJECTION THIS DRAWING AND DESIGN RE...

Страница 5: ...no obstructions such as ceiling joists and that there is sufficient clearance for the housing Check that the electrical wiring can be routed from the wall switches to the mounting location 2 Prepare...

Страница 6: ...not be installed in a place that suffers from severe water leakage 1 Shut power off before cleaning or maintenance 2 Remove grille and wipe it with care using a damp soft cloth with a mild detergent...

Страница 7: ...horised Dealer or Reseller c will not apply where the defect in or failure of the product is attributable to misuse abuse accident or non observation of the manufacturer s instructions This product mu...

Страница 8: ...Notes IXL Eco Ventflo Template for Cut Out IXL Eco Ventflo 14...

Страница 9: ...ers Sampford IXL Pty Ltd Service Department 421 Smith St Fitzroy Victoria 3065 Australia Phone 1300 727 421 Fax 1300 727 425 aftersalesservice sampfordixl com au info sampfordixl com au www sampfordix...

Отзывы: