3.4.1.4 To charge the battery with 230v hook up.
The 230v system has a built in battery charger located within the P.D.U. under the LH bench seat.
When the hook up power is on the charger will work automatically and charge the battery when
required.
Do not use:
•
With a generator set with a non stabilised output voltage.
•
With a mains power voltage exceeding the rated value 230v +/-10%
•
Without a battery in the circuit.
3.4.1.5 Removing and Replacing the Battery.
Remove.
1.
Turn off all appliances.
2.
Disconnect 230v supply if fitted.
3.
Un-strap the battery box and lift off the lid.
4.
Using a spanner disconnect the battery at the negative “-“ terminal first followed by the
positive “+” terminal.
Avoid contacting the two terminals simultaneously with the spanner.
5.
Un-plug the vent pipe.
6.
Lift out the battery.
Replace.
1.
Check all appliances are switched off.
2.
Check the battery box is clean inside and remove any debris.
3.
Lift in the battery into the box.
4.
Reconnect the vent pipe ensuring it exits though the trailer floor.
5.
Using a spanner connect the positive “+” terminal followed by the negative “-“ terminal.
6.
Place the lid and strap up the battery box.
7.
Reset the clock on the control panel. See 3.4.1.2
Exhausted batteries shall be disposed of in accordance with existing environmental protection
regulations.
Any replacement of an auxiliary/leisure battery should be of the same type and specification as that
originally fitted and fit within the battery box.
Содержание Eventa L Tandem
Страница 2: ...Blank Page...
Страница 53: ...5 3 3 2 Eventa L Partition Positions 2 Horses 1 Horse 3 Ponies Empty...
Страница 68: ...8 Electrical Diagrams 8 1 Trailer Lighting Diagram...
Страница 69: ...8 2 12v Living Area Diagram...
Страница 70: ...8 3 230v Diagram...
Страница 71: ...8 4 Base Trailer Diagram...