103—Query/Rate Control:
This command is used to control the output of standard NMEA messages GGA, GLL, GSA,
GSV, RMC, and VTG. Using this command message, standard NMEA messages may be polled
once, or setup for periodic output. Checksums may also be enabled or disabled depending on the
needs of the receiving program. NMEA message settings are saved in battery-backed memory
for each entry when the message is accepted.
Table 16 contains the input values for the following examples:
1. Query the GGA message with checksum enabled
$PSRF103,00,01,00,01*25
2. Enable VTG message for a 1 Hz constant output with checksum enabled
$PSRF103,05,00,01,01*20
3. Disable VTG message
$PSRF103,05,00,00,01*21
Table 16: Query/Rate Control Data Format