- 25 -
Operation
1) When the pump is powered for the first time, built-in program
version is shown and then manual waiting mode appears. When
pump is powered on and after the second time, pump starts with
the status of when pump was turned off last time.
2) In manual waiting mode, push start/stop key
to start pump. If
the key is pushed again, pump stops and moves to manual waiting
mode.
3) When pressing
key for 3 seconds in either manual waiting
mode, EXT waiting mode or during manual operation, the key
lock function can be active. In this state all the key operations are
ineffective. Release the key lock function by pressing
key for
3 seconds again.
4) EXT mode is to operate pump by external signal.
In manual waiting mode, push key as pressing key to move
to EXT mode. To stop pump, push
key to move to manual
waiting mode.
5) To select pulse dividing or pulse multiply, push key in EXT
mode to move to the selection display of pulse dividing/pulse
multiply.
6) To change the pulse dividing/pulse multiply ratio, Push key in
EXT mode to move to the setting display of pulse dividing/pulse
multiply ratio.
7) To display spm indication of EXT operation, push key while
pushing key in EXT mode to move to the display selection
mode of EXT operation.
8) Setting of anti-chattering and STOP function are used in order to
change the factory setting value.
9) To change the setting of anti-chattering, push key as pressing
key to move to move to anti-chattering setting display. Push
key to set and push
key to confirm it and return to manual
waiting mode.
Note 1. This value is used as the upper limit stroke rate of EXT mode as well.
2.
One push changes stroke rate one by one. When keeping up or down
key pressed, figure changes continuously.
3.
The larger the value is, the stronger against disruption of input pulse it
becomes, however, it gets harder for the pump to detect pulses if ON
time gets shorter. The value is approx. time (msec) for the pump to
detect pulse. Set the ON time of input pulse larger than chattering value.
4.
If M-ON is selected, pump starts operation upon returning to manual
waiting if STOP signal is inputted. Pay attention each time of changing
setting.
10) To change STOP setting, first push key as pressing key in
manual waiting mode to move to anti-chattering setting display.
And then push key once to move to STOP setting display. Push
key to select M-ON or M-OF and push
key to confirm it
and move to manual waiting mode.
For details, refer to Operation: 2-3-8.
Caution
Each setting after change is not stored unless
key is
pushed. Do not turn off power before pushing
key.
2-2. Parameter
Step
1 (Note 2)
–
–
1 (Note 2)
–
Parameter
Stroke rate (spm) (Note 1)
Anti-chattering (Note 3)
STOP (Note 4)
Selection of
pulse dividing/multiply
Dividing ratio
Multiply ratio
Set range
1 ~ 360
T-5/T-10/T-50
M-OF/M-ON
/NNN, XNNN
1~999
1~999
Factory set
360
T-5
M-OF
/NNN
1
1
EXT
Manual
Mode
–
Display selection mode
EX/SP
EX
1 (Note 2)