![IWAKI EHN-B11SH Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/iwaki/ehn-b11sh/ehn-b11sh_instruction-manual_2097947019.webp)
- 18 -
Installation
6) Mount control cover and mount the controller in the reverse proce-
dure of above items 1) and 2).
Tightening torque of each screw is as follows:
Screw : 0.39N.m
Screw : 0.39N.m
Screw : 0.8N.m
Caution
Do not forget to mount gaskets
and
. Without them, liquid
may get into controller and controller may be failed.
Wiring to socket
for signal input
Terminal for
power source
Plug
H
Socket
Potential free contact signal
Open collector signal
Socket
STOP signal
STOP signal
EXT signal
EXT signal
4
5
6
4
5
6
5) Remove plug
from socket
. Connect a signal cord to the
plug
with screw driver and mount it on the socket
. Pull the
signal cord from the outside of the control unit to adjust the slack
and then mount the cord nut
securely by hand. (The cord is
sealed by cord gasket
.)