- 23 -
Maintenance
3. Disassembly & Assembly
Tool
AMP40-1, AMP50-1
Spanner
13 mm, 19 mm, 24 mm
1 pc/each
Plastic welder or
industrial dryer
1 unit
Hand press
1 unit
Remarks
Hex. wrench
4 mm, 5 mm
1 pc/each
Plastic round bar
34 mm dia. × 100 L
To remove & mount bearing
Plastic hammer
1 pc
●
Pay attention to magnet field
The magnet drive pump has a pair of strong magnets. The strong magnet field
could adversely affect the persons who are assisted by electronic devices
such as the pacemaker.
●
Do not catch the finger
The magnet force of the pump is powerful. Take care not to catch the finger in
the bracket.
●
Wear protective clothing
Coming in contact with a harmful chemical liquid may cause eye or skin trou-
ble. Wear protective clothing such as a protective mask, goggles, gloves dur-
ing the work.
●
Turn off power during the maintenance work
Risk of electrical shock. Make sure the power source is turned off, and the
pump and devices are stopped prior to the work.
WARNING
Turning off power
Prohibited
Wear protective
gear
Caution
●
Pay attention to magnet force
The magnet force is powerful. Take care so that iron pieces and iron powder do not
stick to the magnet of pump.
●
The powerful magnet force can break the data of the magnetic card, disc or so. Do not
have the magnetic product close to the magnet of pump.
CAUTION
Tool list
Following tools are necessary to disassemble and assemble the pump.
Содержание AMP 40
Страница 6: ...4 Outline 1 Unpacking Inspection 5 2 Model code 6 3 Operating conditions 7 4 Part names 8...
Страница 11: ...9 Installation 1 Before installation 10 2 Piping 11 3 Wiring 14 4 Protection equipment 14...
Страница 17: ...15 Operation 1 Before operation 16 2 Operation 17 3 Shutdown 17...
Страница 20: ...18 Maintenance 1 Troubleshooting 19 2 Maintenance Inspection 21 3 Disassembly Assembly 23 4 Spare Wear parts 29...