Control panel
6 720 645 172
(2010/07) en
9
B
Use
for more information under
Info
.
Shows the actual value for a given sensor and the set
point for E11.T1.
Shows the actual value and stop temperature for the hot
water sensor as well as the mixing valve position. Is only
shown in heat pumps that produce hot water.
Shows the actual value for the given sensors.
0 = Off, 1 = On (
Æ
Chapter 2, page 4 for information on
I/O-connections).
Shows present utilisation in % (
Æ
Chapter 2, page 4 for
information on I/O-connections).
B
Use
several times to return to the Initial menu.
Information is also available at different places in the
menus, e.g. under
Temperatures
at the top menu level.
3.11 Access levels
Log in must be done per heat pump.
Log in as a customer:
B
Press
for 5 seconds in the Initial menu.
Log in as installer:
B
Enter password mmdd under
Access level
.
mm = current month
dd = current day
E.g.: 0315 = 15th March.
Logging out:
B
Use function
Quick log-out
on installer level or wait.
External sensors
E11.T1
35:2 °C
E11.T1 spv
36.2 °C
E10.T2
3.9 v °C
Tab. 23 External sensors 1
External sensors
E41.T3
56.4 °C
Stop
57.0 °C
E41.Q11
Off
Tab. 24 External sensor 2
Internal sensors
T6 87.0
( °C)
T8 36.2
T10 5.0
T9 29.2
T11 2.0
Tab. 25 Internal sensors
Status digital I/O
vvvvv1 2 3 4 5 6 7 8
In: vv0 0 0 1 1 1 1 1
Out: 1 0 0 0 1 0 1
Tab. 26 Status digital I/O
Status analogue out
Ao1: 0.0
(%)
Ao2: 0.0
Ao4: 64:3
Ao3: 0.0
Ao5: 52.8
Tab. 27 Status analogue out
Program version
x.x – x – xx
Tab. 28 Program version
Not logged in
See a small number of settings.
Customer
See and change customer settings.
Logging out after 10 min.
Installer
According to the Customer and see
and change more settings. Logging
out after 30 min.
Tab. 29 Access levels
ok