16
EN
Instruction manual
TROUBLESHOOTING
CAUTION! Switch off and remove plug from mains before investigating fault.
Conventional trouble
Trouble reason
Remedy
Motor does not start.
∙
The chain brake has been
activated.
∙
Turn the chain brake initiator to
“position 1” .
∙
Power supply is absent.
∙
Check power supply.
∙
The outlet is defective.
∙
Try another outlet, replace the
outlet if necessary.
∙
The power cord or extension
cord or plug is damaged.
∙
Check and replace if
necessary.
Motor shuts down.
∙
The extension cord is damaged.
∙
Check the cable, replace if
necessary.
∙
Loose outer contact.
∙
Contact an authorized IVT
service center.
∙
Loose inner contact.
∙
Contact an authorized IVT
service center.
∙
On/off switch malfunctions.
∙
Contact an authorized IVT
service center.
Dry saw chain.
∙
There is not enough oil in the oil
reservoir.
∙
Top up oil.
∙
Ventilation slots in the oil
reservoir or oil output channel
clogged up.
∙
Clean.
∙
The oil output channel is
clogged up.
∙
Clean.
The saw chain doesn’t work.
∙
Problems with the switching
mechanism in the forward component
of the chain brake initiator.
∙
Contact an authorized IVT
service center.
The saw chain / guide bar heat
up considerably.
∙
There is not enough oil in the oil
reservoir.
∙
Top up oil.
∙
Ventilation slots in the oil
reservoir or oil output channel
clogged up.
∙
Clean.
∙
The oil output channel is
clogged up.
∙
Clean.
∙
The saw chain is under too
much stress.
∙
Correct the tension of the saw
chain.
∙
The saw chain is dulled.
∙
Sharpen or change the saw
chain.