7. Maintenance, Cleaning and Diagnosis
7.6 Replacing the press plunger
The press plunger may be replaced if required. In order to facilitate replacing the press plunger, the following procedure
must be followed.
Step 1:
Remove the attachment screw.
Remove the screw (C) while the furnace head is closed.
Step 2:
Remove the press drive cover.
First firmly push the cover to the back (arrow 1) and then remove it
by lifting it (arrow 2).
Step 3:
Loosen the press plunger.
Unscrew the clamping screw of the press plunger (64) by turning it
approx. one half turn.
63
65
64
67
c