background image

18

5.  Operation and Configuration 

5.1  Introduction to the operation

The Programat CS4 is equipped with a graphic display with 
backlighting. The numeric and command keys can be used to  
program and control the furnace. 

 

5.2  Explanation of the key functions 

–  Settings key (78) 

  After pressing the Settings key, the settings required for the  

furnace can be displayed one after the other and changed, if  
necessary.

–  Information key (81)

  After pressing the Information key, information about the furnace 

can be displayed one after the other.

–  Cursor keys (79, 80)

  In the stand-by display, the cursor keys can be used to change the 

program.  

  The cursor keys are also used to scroll through the settings or 

information pages.

  In the parameter list, the current cursor position is indicated by a 

solid (non-flashing) frame around the numeric value. 

–  –/+ keys (76, 77)

  Changing the settings or entering a numeric value is achieved by 

means of the -/+ keys.

  Each entry by means of the – or + key is immediately accepted, 

provided the corresponding value range is observed. Once the  
value range limit has been reached, the value can no longer be 
changed.

–  ESC key (71)

  This key is used to end the error display. Furthermore, any page of 

the display can be left with this key.

–  ENTER key (72)

  With this key, settings may be changed or entries confirmed.

–  Start key (73)

  This key starts the selected program. 

–  Start LED (74)

  Lights up once a program has started. It flashes when the  

program is paused.

–  Stop key (75)

  Pressing 1 x (pause program)
  Pressing 2 x (program is aborted) The STOP key also stops the  

furnace head movement and the acoustic signal.

–  Open furnace head key (87)

  Furnace head is opened (not during a program in progress, or if 

the temperature in the sintering chamber is higher than 
1200 °C/2192 °F). 

–  Close furnace head key (88)

  Furnace head is closed (not during a program in progress).

–  Program 1 key (82)

  Program 1 (P1) is selected with this key (not during a program in 

progress).

–  Program 2 key (83)

  Program 2 (P2) is selected with this key (not during a program in 

progress).

–  Program 3 key (84)

  Program 3 (P3) is selected with this key (not during a program in 

progress).

–  Program 4 key (85)

  Program 4 (P4) is selected with this key (not during a program in 

progress).

–  Next program key (86)

  The next program (P5, P6, ...) is selected with this key (not during 

a program in progress).

5.3 Basic meaning of the display readouts

– Stand-by

–  Program progress indicator

Status area

Recommendation 
area

The corresponding symbol 
suggests the next, most 
likely action (keystroke).

Furnace or  
program status

Current temperature 
of the furnace

Main area

In the main area, the most 
important information 
(e.g. the currently selected 
program) is indicated.

Status area

Progress bar

Remaining time 
(hh:mm)

Furnace or  
program status

Current temperature 
of the furnace

Main area

Currently selected 
program

78

81

79

80

77

82

83

84

85

86

72

71

74

73

75

76

88

87

Содержание Programat CS4

Страница 1: ...Programat CS4 Operating Instructions...

Страница 2: ......

Страница 3: ...5 5 Settable parameters and possible value ranges 5 6 Settings test programs and information 5 7 Explanation of the display symbols 5 8 Explanation of the acoustic signals 5 9 OSD 6 Practical Use 23 6...

Страница 4: ...nics plug 24 Leave spring 25 Air vents base 26 Cooling tray 27 Cooling tray fastening screw 28 Silicone washer 29 Hood 30 Attachment screw for hood 31 Air vents furnace head 32 Air vents rear panel 33...

Страница 5: ...5 44 16 26 4 8 27 28 15 25 1 3 6 5 37 7...

Страница 6: ...6 39 17 22 18 23 21 20 9 38 46 47 19 24 35 9 10 11 10 11 14 31 30 29 42 45 13 12 32 42...

Страница 7: ...key 81 Information key 82 Program 1 key 83 Program 2 key 84 Program 3 key 85 Program 4 key 86 Next program key 87 Open furnace head 88 Close furnace head 100 Sinter tray 102 Cleaning brush 103 IPS e m...

Страница 8: ...crushing The Operating Instructions must be read 1 3 Notes regarding the Operating Instructions Apparatus Programat CS4 Target group Dentists dental professionals These Operating Instructions facilit...

Страница 9: ...ust be operated under the indicated environmental and operating conditions see chapter 9 The Programat CS4 must be properly maintained Do not use colouring liquids containing chlorine or hydro chloric...

Страница 10: ...ace 2 1 10 Contraindication Do not insert any foreign objects into the air vents There is a risk of electric shock 2 1 11 Burn hazard Never place objects in the hot firing chamber by hand since there...

Страница 11: ...ks and dangers may perform these procedures After maintenance the required safety tests high voltage resistance protective conductor etc have to be carried out Ensure that only fuses of the indicated...

Страница 12: ...uctor Protection from electric shock Electric fuses Protection from electric shock Furnace housing and end caps Protection from electric shock burning and crushing 3 3 Description of functions The sin...

Страница 13: ...2 4 5 2 3 4 5 3 1 5 2 3 4 5 3 4 2 Selecting the location Place the furnace on a fire proof flat table using the rubber feet Make sure that the furnace is not placed in the immediate vicinity of heater...

Страница 14: ...strongly against the rear of the furnace For safety reasons the spacer must always be mounted Secure the cooling tray 26 with the two screws 27 including the silicone washers 28 Place the cooling tra...

Страница 15: ...er on the furnace head and carefully position it on the furnace head mounting 35 Ensure that the furnace head mounting mark 33 is aligned with the furnace base mounting mark 34 Make sure that the sint...

Страница 16: ...tablishing additional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 12 with the power socket...

Страница 17: ...1 Connect the power cord 12 with the wall socket 2 Put the On Off switch 9 at the rear of the furnace on position I Subsequently the furnace conducts an automatic self test The performance of all furn...

Страница 18: ...tarts the selected program Start LED 74 Lights up once a program has started It flashes when the program is paused Stop key 75 Pressing 1 x pause program Pressing 2 x program is aborted The STOP key a...

Страница 19: ...ive error number is indicated Value range C Value range F Symbol Parameters min max Unit min max Unit v1 Predrying stage 1 Predrying temperature 0 100 300 C 0 212 572 F V1 Predrying time 00 00 00 20 h...

Страница 20: ...red volume can be set using the keys Melody The desired melody may be set using the keys Programming Enables the programming of the parameters for the currently selected program Settings Display Short...

Страница 21: ...C or F Calibration value MHT Calibration value at 1500 C 2732 F The value is displayed in accordance with the selected temperature mode in C or F Information Display Short Description Mains voltage Sh...

Страница 22: ...ith the error tune endless beep The beeper may be switched off with the STOP key while the error message still remains visible If the error message is acknowledged with ESC the beeper also stops At th...

Страница 23: ...2 Loading for sintering procedure The sinter tray 100 holds up to approximately 6 units depending on the program Make sure that the objects do not touch in order to prevent them from sintering togeth...

Страница 24: ...icates a temperature below 400 C 752 F Step 2 Open the furnace head using the open furnace head key 87 Use a sinter tray fork to place the loaded sinter tray into the furnace Step 3 Press the Start ke...

Страница 25: ...a Settings Renaming the keyboard can be selected provided the currently selected program is not write protected The desired letters can be selected using the cursor keys circular The letter is selecte...

Страница 26: ...rticles see image a Fine glass dust The insulation of the lower part of the furnace and the cooling tray show residue of fine glass dust This type of contamination is more difficult to discern 7 1 2 C...

Страница 27: ...be cleaned from time to time What When Cleaning material Furnace housing 7 and furnace head if required soft dry cloth Membrane sealed keypad 8 weekly soft dry cloth Cooling tray 26 daily cleaning bru...

Страница 28: ...UTH 1 Press the Settings key 78 to access the Settings screen Select Temperature Calibration UTH using the cursor keys 79 80 The following display appears The UTH calibration program is selected with...

Страница 29: ...correction value can be transferred to the furnace with the help of the keys Each keystroke changes the furnace temperature by 1 C The correction value must be added to the current temperature of the...

Страница 30: ...oltage The furnace is operated with the incorrect supply voltage Make sure that the furnace is operated with the supply voltage indicated on the rating plate 1310 Calibration reminder Some time has pa...

Страница 31: ...ement bent or fractured Switch off the furnace and contact the Ivoclar Vivadent After Sales Service Damage of the thermocouple Is the thermocouple damaged or fractured Contact the Ivoclar Vivadent Aft...

Страница 32: ...kg Furnace head 17 kg Safety notes The sinter furnace complies with the following standards IEC 61010 1 2010 EN 61010 1 2010 UL 61010 1 2012 2015 CSA 61010 1 2012 2015 IEC 61010 2 010 2014 EN 61010 2...

Страница 33: ...contact the Ivoclar Vivadent Service Center Important information The current program tables are also available at www ivoclarvivadent com The program tables can be downloaded from the Internet as PDF...

Страница 34: ......

Страница 35: ......

Страница 36: ...ivadent S A de C V Calzada de Tlalpan 564 Col Moderna Del Benito Ju rez 03810 M xico D F M xico Tel 52 55 50 62 10 00 Fax 52 55 50 62 10 29 www ivoclarvivadent com mx Ivoclar Vivadent BV De Fruittuine...

Отзывы: