background image

Calibration of Loaded Forks 

Position the electric pallet truck into the skid load with 

your known load weight

.                                                  - 

Lower the

 loaded forks to the ground and make sure that no pressure is in the system.    

(In our example the known load weight is 4000 pounds) 

Start entering the known load weight into the digital indicator by using the 

arrow up button to toggle digits 0-9 and  

‘M’ button to move from right to left beginning with mode 1 to mode 5.  If there is only four digits in your  
known load weight, 9999 or less, mode 5 must be input as 0. 

Start with least significant digit of your known load weight. 

- Use the 

“M”

 button to increment to next digit on the LED display 

Repeat this procedure until the 

Mode 

digit display is showing number 

5.

                                                                 

Note:

 Since in our example of 4000 pounds known load weight value has only four digits 

make sure that the 5th least significant digit has 

“0”

 value entered into the calibration 

system.

With  loaded forks on the ground

 and no pressure in the system 

press the ‘

M’

 

button to advance to

 Mode

 

6. 

When the digital indicator shows

 Mode 6,

 activate and 

hold lift control button

.                

The pressure transducer readings and specific algorithm calculations will 

stop the lift 

cylinder at predetermined height. 

The LED display will go blank for the moment, internal 

audio will be activated and within few seconds will show the calibrated known load weight of 
4000.                                                                                                                                        

(In your case the known calibrated load weight will be shown!)  

     

The ED2-EP system weighing calibration is done  

When you lower the loaded forks to the ground 

Mode ‘8’ 

will show on the LED display.  This indicates 

that the system is calibrated and ready to weigh.  

Mode ‘8’

 is the starting point for all weighing 

procedure.

 

Mode 1 ‘0’ 

400[0]

Mode 2 ‘0’ 

40[0]0

Mode 3 ‘0’ 

4[0]00

Mode 4 ‘4’ 

[4]000

Mode 5 ‘0’ 

[0]4000

!

!

!

!

!

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

www.skidweigh.com

 

  

Содержание SkidWeigh DL2E-EPSeries

Страница 1: ...ual Electric Pallet Truck Check Weighing Systems SkidWeigh Series ED2E EP and DL2E EP ED2E EP V1500 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power On Off Switch ...

Страница 2: ...er with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected ...

Страница 3: ...r nal relay is controlled by the microprocessor and activated only during the load weighing cycle There is no power connected to these two BLACK wires Internal relay configuration is SPDT Method A Preferred Method Use the two BLACK wires to splice them in series with the operator activated lift control switch wire or signal wire from the electronic controller that is activating the lift pump motor...

Страница 4: ...ed vehicle is motion may produce hydraulic spikes that are detected by the pressure transducer sending a signal this may be seen by the vehicle controller as starting the weighing cycle Short interruption of the power to the lift solenoid coil on some controllers are seen as a fault and power to the vehicle will be cut SkidWeigh ED2E EP DL2 EP Power Off When weighing function is not required and to...

Страница 5: ...ower Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wire connected to the ignition switch Automotive 60 V load dump protection Reversal power supply protection Weighing Function Calibration Procedure The SkidWeigh ED2E EP DL2 EP calibration is automatic and is done by liftin...

Страница 6: ...own for approximate 5 seconds After 5 seconds the Mode 8 digit will change to Mode 0 Press and hold the lift button to initiate the automatic weighing cycle Continue to hold until the system lift interrupt stops the lift range The system will develop an algorithm calculation and determine the correct height to stop the lift cylinder The LED display will go blank momentarily internal audio will be ...

Страница 7: ... 5th least significant digit has 0 value entered into the calibration system With loaded forks on the ground and no pressure in the system press the M button to advance to Mode 6 When the digital indicator shows Mode 6 activate and hold lift control button The pressure transducer readings and specific algorithm calculations will stop the lift cylinder at predetermined height The LED display will g...

Страница 8: ...the measurement The weighing cycle will be initiated and the system will automatically stop the lift cylinder when ready and load weight will be shown Audio will be deactivated The lift cylinder will be operational once the load weight is shown on the LED display Mobile Wireless Bluetooth Printer The SkidWeigh ED2 EP DL2 EP Elite series can be ordered to support Bluetooth mobile printers The autom...

Страница 9: ...ED display until next time the forks are lowered to ground Note2 When vehicle in motion the LED might show some random load weight This is due to the hydraulic spikes and this does not represents any actual load weight value Note 3 During the normal operation if you do not want to use the weighing function turn off the main power switch located on the top of the housing LED display will not show an...

Отзывы: