Calibration of Loaded Forks
Position the electric pallet truck into the skid load with
your known load weight
. -
Lower the
loaded forks to the ground and make sure that no pressure is in the system.
(In our example the known load weight is 4000 pounds)
Start entering the known load weight into the digital indicator by using the
arrow up button to toggle digits 0-9 and
‘M’ button to move from right to left beginning with mode 1 to mode 5. If there is only four digits in your
known load weight, 9999 or less, mode 5 must be input as 0.
Start with least significant digit of your known load weight.
- Use the
“M”
button to increment to next digit on the LED display
Repeat this procedure until the
Mode
digit display is showing number
5.
Note:
Since in our example of 4000 pounds known load weight value has only four digits
make sure that the 5th least significant digit has
“0”
value entered into the calibration
system.
With loaded forks on the ground
and no pressure in the system
press the ‘
M’
button to advance to
Mode
6.
When the digital indicator shows
Mode 6,
activate and
hold lift control button
.
The pressure transducer readings and specific algorithm calculations will
stop the lift
cylinder at predetermined height.
The LED display will go blank for the moment, internal
audio will be activated and within few seconds will show the calibrated known load weight of
4000.
(In your case the known calibrated load weight will be shown!)
The ED2-EP system weighing calibration is done
When you lower the loaded forks to the ground
Mode ‘8’
will show on the LED display. This indicates
that the system is calibrated and ready to weigh.
Mode ‘8’
is the starting point for all weighing
procedure.
Mode 1 ‘0’
400[0]
Mode 2 ‘0’
40[0]0
Mode 3 ‘0’
4[0]00
Mode 4 ‘4’
[4]000
Mode 5 ‘0’
[0]4000
!
!
!
!
!
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7