background image

General Installation Guide 

This 

SkidWeigh Series ED2E-EP / DL2E-EP

 system installation & calibration guide describes how to install, calibrate, 

test and use your electric pallet truck on-board weighing system. Following the instructions in this guide will enable you 
to  get  your  system  setup  and  operating  quickly.    In  the  event  that  you  require  additional  assistance,  please  contact 
customer support via e-mail at [email protected]visit 

www.skidweigh.com

  or contact us at the address and or 

contact number below: 

Integrated Visual Data Technology Inc.   

                                                                                                                        

3439 Whilabout Terrace, Oakville, ON, Canada, L6L 0A7                                                                                            
Phone: 905-469-0985 

Safety 

Always disconnect the vehicle battery while installing SkidWeigh systems or any other electronic product.                   
Make sure that unit, pressure transducer and any other associated cables are securely mounted and do not impede any 
of the vehicle’s controls. Use care when routing the component cables. Route the cables where they will be protected. 
Use commonly accepted install practices for after market industrial vehicle electronic devices.                                      
The installation of the SkidWeigh systems should only be performed by a knowledgable lift truck dealer technician or end 
user with electro and hydraulic experience.                                                                                                                                                                          
Here are two acceptable methods of making a wire connections:                                                                                            
* Soldering your connections (recommended)                                                                                                                     
* Crimp connectors ( with the use of the proper crimping tool)                                                                               
Regardless of the method you choose, ensure that the connection is mechanically sound and properly insulated. Use 
high quality electrical tape and shrink tubing where necessary. This product is connected directly to the vehicle’s ignition 
switch, operating voltage from 12 to 55 VDC. 

Electro-Magnetic Compatibility 

CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2 
and EN 61326-1 interference emit EN 61000-6-3, EN 61326-1 for the pressure transducer. 

SkidWeigh ED2E-EP / DL2E-EP Series 

Our policy is one of continuous improvement and the information in this document is subject to change without notice. 
Check that software version displayed on LED is the one applicable for your application. 

Overview of Components 

The standard

 SkidWeigh ED2E-EP / DL2-EP

 

Series

 check weighing system consist of the following components:                                                   

* Digital indicator with wiring harness, mounting bracket and anti-vibration mount                                                              
* Hydraulic pressure transducer with 3 wires cable                                                                                                             
* Installation & Calibration manual and operator usage instruction                                                                                                                              

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

www.skidweigh.com

 

  

Содержание SkidWeigh DL2E-EPSeries

Страница 1: ...ual Electric Pallet Truck Check Weighing Systems SkidWeigh Series ED2E EP and DL2E EP ED2E EP V1500 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power On Off Switch ...

Страница 2: ...er with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected ...

Страница 3: ...r nal relay is controlled by the microprocessor and activated only during the load weighing cycle There is no power connected to these two BLACK wires Internal relay configuration is SPDT Method A Preferred Method Use the two BLACK wires to splice them in series with the operator activated lift control switch wire or signal wire from the electronic controller that is activating the lift pump motor...

Страница 4: ...ed vehicle is motion may produce hydraulic spikes that are detected by the pressure transducer sending a signal this may be seen by the vehicle controller as starting the weighing cycle Short interruption of the power to the lift solenoid coil on some controllers are seen as a fault and power to the vehicle will be cut SkidWeigh ED2E EP DL2 EP Power Off When weighing function is not required and to...

Страница 5: ...ower Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wire connected to the ignition switch Automotive 60 V load dump protection Reversal power supply protection Weighing Function Calibration Procedure The SkidWeigh ED2E EP DL2 EP calibration is automatic and is done by liftin...

Страница 6: ...own for approximate 5 seconds After 5 seconds the Mode 8 digit will change to Mode 0 Press and hold the lift button to initiate the automatic weighing cycle Continue to hold until the system lift interrupt stops the lift range The system will develop an algorithm calculation and determine the correct height to stop the lift cylinder The LED display will go blank momentarily internal audio will be ...

Страница 7: ... 5th least significant digit has 0 value entered into the calibration system With loaded forks on the ground and no pressure in the system press the M button to advance to Mode 6 When the digital indicator shows Mode 6 activate and hold lift control button The pressure transducer readings and specific algorithm calculations will stop the lift cylinder at predetermined height The LED display will g...

Страница 8: ...the measurement The weighing cycle will be initiated and the system will automatically stop the lift cylinder when ready and load weight will be shown Audio will be deactivated The lift cylinder will be operational once the load weight is shown on the LED display Mobile Wireless Bluetooth Printer The SkidWeigh ED2 EP DL2 EP Elite series can be ordered to support Bluetooth mobile printers The autom...

Страница 9: ...ED display until next time the forks are lowered to ground Note2 When vehicle in motion the LED might show some random load weight This is due to the hydraulic spikes and this does not represents any actual load weight value Note 3 During the normal operation if you do not want to use the weighing function turn off the main power switch located on the top of the housing LED display will not show an...