Operational Principal 

The 

SkidWeigh  ED2E-EP  /  DL2E-EP

  system  operation  principal  is 

based  on  the  hydraulic  pressure  transducer  mounted  in  the  vehicle 
lifting  hydraulic  circuit.    The  increase  in  the  hydraulic  pressure  will 
activate  the  specific  “weighing  cycle”  algorithm  and  initiate  automatic 
motion control of the hydraulic lift motor. The microprocessor will take a 
readout  of  the  predetermined  valid  pressure  transducer  input  at  a 
sample  rate  of  16000  readings  per  measurement  session  and  will 
convert it to the load weight that will be shown on LED display. 

Pressure Transducer Installation 

The pressure transducer must be installed in the lifting hydraulic line

 

between the lift control valve and lift cylinder. 

Mount a T-piece in hydraulic line for the installation of the pressure transducer.    

2 Methods for Automatic Pump Motor De-Activation During Load 
Weighing Cycle 

Two 

BLACK wires 

are connected to the internal relay located in the 

ED2E-EP / DL2E-EP

 digital indicator. The inter-

nal relay is controlled by the microprocessor and activated only during the load weighing cycle. 

There is no power 

connected to these two BLACK wires !  

I

nternal relay configuration is SPDT.    

                                                                                                                                                                                                                                                    

Method A.

 

(Preferred Method)

Use the two 

BLACK wires to “splice” them in series 

with the operator activated 

lift control switch 

wire or signal 

wire from the electronic controller that is activating the lift pump motor solenoid.   

 

 

                                                                                                                                                                   

Note:

 

The predetermined motion of the lifting cylinder and the load weight measurement “weighing cycle” will be 

initiated and controlled automatically by the software algorithm based on the input signal from the pressure trans-
ducer. Once the load weight is shown on the LED display the internal relay will be de-activated and the lift pump 
motion control will be back to normal operation .

 

(With the vehicle at a stationary position during the lifting cycle 

diagnostic display on some vehicles may show ‘No power to lift motor’ or audio signal might be activated for 
short time period.)

      

  

Consult Vehicle Wiring Diagram ! 

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

www.skidweigh.com

 

  

Operator Activated  

Lift Pump Motor Control Switch

Содержание SkidWeigh DL2E-EPSeries

Страница 1: ...ual Electric Pallet Truck Check Weighing Systems SkidWeigh Series ED2E EP and DL2E EP ED2E EP V1500 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power On Off Switch ...

Страница 2: ...er with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected ...

Страница 3: ...r nal relay is controlled by the microprocessor and activated only during the load weighing cycle There is no power connected to these two BLACK wires Internal relay configuration is SPDT Method A Preferred Method Use the two BLACK wires to splice them in series with the operator activated lift control switch wire or signal wire from the electronic controller that is activating the lift pump motor...

Страница 4: ...ed vehicle is motion may produce hydraulic spikes that are detected by the pressure transducer sending a signal this may be seen by the vehicle controller as starting the weighing cycle Short interruption of the power to the lift solenoid coil on some controllers are seen as a fault and power to the vehicle will be cut SkidWeigh ED2E EP DL2 EP Power Off When weighing function is not required and to...

Страница 5: ...ower Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wire connected to the ignition switch Automotive 60 V load dump protection Reversal power supply protection Weighing Function Calibration Procedure The SkidWeigh ED2E EP DL2 EP calibration is automatic and is done by liftin...

Страница 6: ...own for approximate 5 seconds After 5 seconds the Mode 8 digit will change to Mode 0 Press and hold the lift button to initiate the automatic weighing cycle Continue to hold until the system lift interrupt stops the lift range The system will develop an algorithm calculation and determine the correct height to stop the lift cylinder The LED display will go blank momentarily internal audio will be ...

Страница 7: ... 5th least significant digit has 0 value entered into the calibration system With loaded forks on the ground and no pressure in the system press the M button to advance to Mode 6 When the digital indicator shows Mode 6 activate and hold lift control button The pressure transducer readings and specific algorithm calculations will stop the lift cylinder at predetermined height The LED display will g...

Страница 8: ...the measurement The weighing cycle will be initiated and the system will automatically stop the lift cylinder when ready and load weight will be shown Audio will be deactivated The lift cylinder will be operational once the load weight is shown on the LED display Mobile Wireless Bluetooth Printer The SkidWeigh ED2 EP DL2 EP Elite series can be ordered to support Bluetooth mobile printers The autom...

Страница 9: ...ED display until next time the forks are lowered to ground Note2 When vehicle in motion the LED might show some random load weight This is due to the hydraulic spikes and this does not represents any actual load weight value Note 3 During the normal operation if you do not want to use the weighing function turn off the main power switch located on the top of the housing LED display will not show an...