![IVDT SkidWeigh Classic SC5 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ivdt/skidweigh-classic-sc5-series/skidweigh-classic-sc5-series_installation-and-calibration-manual_2097236008.webp)
Calibration of Loaded Forks
* Have known calibration load weight near by
(Kg or pounds depending on your needs)
*
Position the forks into the skid with your known load weight.
* In our
example
the known load weight is
4000.
* Start entering into the system known load weight (
Use paper clip)
.
Start entering with first least
significant digit of your known load weight.
- Use
“M”
button to shift from right to left beginning with
Mode 1 digit
to
Mode 6 digit.
- Use “
Arrow Up”
button to input known weight (increments from 0 to 9 with wrap around)
Note:
In our example we have value of
4000
(four digits only). Make sure that 5th digit is
“0”
value.
*
Next step is to press
”M”
button to advance to
Mode 6
.
*
With loaded forks on the ground and LED Display showing
Mode 6
,
activate and hold
lift control switch until loaded forks are
automatically stopped at pre determined forks height.
*
During the measurement cycle LED Display will go blank for moment
* System is calculating the load weight value
*
The LED Display will show calculated calibrated weight.
* The calibrated value will be stored in the system.
Automatic load weight calibration function is done
Lower the loaded forks to ground
Mode
8
digit will be shown on LED Display
System is ready to be used
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7