IVDT SkidWeigh Classic SC5 Series Скачать руководство пользователя страница 8

Calibration of Loaded Forks                                                                                     

* Have known calibration load weight near by 

(Kg or pounds depending on your needs)                              

Position the forks into the skid with your known load weight.                                                                        

* In our

 example 

the known load weight is

 4000.

                                                                                                                 

* Start entering into the system known load weight (

Use paper clip)

Start entering with first least 

significant digit of your known load weight.  

- Use

 “M”

 button to shift from right to left beginning with

 Mode 1 digit

 to 

 Mode 6 digit.                                                           

 

- Use “

Arrow Up”

 button to input known weight (increments from 0 to 9 with wrap around)  

Note:

 In our example we have value of 

4000 

(four digits only). Make sure that 5th digit is

 “0” 

value. 

*

Next step is to press

 ”M” 

button to advance to

 Mode 6

.   

*

 With loaded forks on the ground and LED Display showing 

Mode 6

activate and hold

 

lift control switch until loaded forks are 

automatically stopped at pre determined forks height. 

*

 During the measurement cycle LED Display will go blank for moment                        

* System is calculating the load weight value

   

The LED Display will show calculated calibrated weight.                               

* The calibrated value will be stored in the system. 

 Automatic load weight calibration function is done 

 

  

Lower the loaded forks to ground                                  

Mode

 8

 digit will be shown on LED Display      

System is ready to be used

 

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

Содержание SkidWeigh Classic SC5 Series

Страница 1: ...ation Calibration Manual Electric Pallet Truck Check Weighing Systems SkidWeigh Classic SC5 and SC5 OEM Series SC5EP Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Страница 2: ...nd user with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is conne...

Страница 3: ...ydraulic line for the installation of the pressure transducer Pressure Transducer Installation Precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free Make sure that the installed pressure transducer will not touch any moving parts or vehicle assembly once installed while in normal operation The pressure transducer has a 1 4 18 NPT male thread Us...

Страница 4: ...indicator in series with disconnected wire and coil terminal The SC5 OEM electric pallet truck weighing systems are the OEM s version Two wires from main wiring harness Yellow and Green wires are used for lift pump motor solenoid interface System is supplied with two extension wires Yellow and Green Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Orange...

Страница 5: ...Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Страница 6: ...ks height for 3 4 seconds Load weight will be calculated and shown on LED indicator display Once the load weight is shown on LED Display the lift pump motor solenoid circuit will be in normal operational mode Electrical Power Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wi...

Страница 7: ...e version for the moment and in Mode 8 will be shown System weighing function is ready to be calibrated Empty Forks Calibration With lowered empty forks on the ground the Mode 8 will shown Use paper clip and press and hold M button for approx 5 seconds Mode 8 will change to Mode 0 Activate and hold lift control switch until lift pump motor stops automatically The LED Display will go blank and with...

Страница 8: ...ue of 4000 four digits only Make sure that 5th digit is 0 value Next step is to press M button to advance to Mode 6 With loaded forks on the ground and LED Display showing Mode 6 activate and hold lift control switch until loaded forks are automatically stopped at pre determined forks height During the measurement cycle LED Display will go blank for moment System is calculating the load weight val...

Страница 9: ... pre determined forks height During the measurement cycle LED Display will go blank for moment System is calculating the load weight value Within few seconds LED Display will show the load weight Our example 583 Depending on system set up application the value could be in pounds or kg Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 System Power Switch N...

Отзывы: