Operational Principal
The
SkidWeigh Classic
systems operation principal is based on the hydraulic pressure transducer mounted in the
vehicle lifting hydraulic circuit. The increase in the hydraulic pressure will activate the specific “weighing cycle” algorithm
and initiate automatic motion control of the hydraulic lift motor. The microprocessor will take a readout of the
predetermined valid pressure transducer input at a sample rate of 16000 readings per measurement session and will
convert it to the load weight that will be shown on LED display.
Pressure Transducer Installation
The pressure transducer must be installed in the lifting hydraulic line
between the lift control valve and lift cylinder.
Mount a T-piece in
hydraulic line for the installation of the pressure transducer.
Pressure Transducer Installation Precautions
Before installation of the pressure transducer the hydraulic lift
circuit must be pressure free.
Make sure that the installed pressure transducer will not
touch any moving parts or vehicle assembly once installed
while in normal operation.
The pressure transducer has a
1/4”-18 NPT male thread
.
Use thread seal to ensure tight fit.
Mounting Location for Digital Indicator
Use the mounting bracket with the anti vibration
mounts and fasten the digital indicator to the
vehicle dashboard, or any other convenient place
on the electric pallet truck body There are many
examples of mounting locations that will depend
on the vehicle model. However, additional
mounting items such as a flat brackets may be
needed to help secure the unit.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7