background image

Menu 1 Functions:

Resolution, Time-lapse Capture, Quality, Sharpness, Exposure, Date Stamp.
1.  Press the Down button to scroll through your choices.
2.  When your setting choice is highlighted, press the OK button.

Set Resolution

1.  Select a resolution from options: 
 WVGA/2M/3M/5M/8M/14M.
2.  Press OK to confirm.

Time-lapse Still Capture:

You can set the device to take images, 
ranging from 2 to 999 images, over a 
defined time period. 
From menu 1, choose Time-lapse Capture 
and press the OK button.

Note: To avoid premature battery power 
drainage, use the AC adaptor.

12

Main Menu 1

Содержание IVAMS04HD

Страница 1: ...Portable Digital HD LCD Microscope User Guide IVAMS04HD ...

Страница 2: ...Product Version Info 17 Troubleshooting 17 Specifications 18 Introduction 3 Safety Precautions 3 FCC Notification 3 Features 4 Included Accessories 4 Parts and Functions 5 Using the Microscope 6 Installing the Battery 6 Charging the Battery 6 Inserting the MicroSDHC Memory Card 6 Operating the Microscope 7 Observation 7 Color Mode 8 Previewing on a Computer Screen 8 Connecting to HDTV Monitor 9 Im...

Страница 3: ...e product away from water and other liquids Do not handle the product with wet hands Never use the product in the rain or snow Moisture creates the danger of fire and electric shock Use your microscope within the 23 to 120 F 5 to 50 C temperature range Try to limit sudden environmental temperature changes as this may create moisture in the microscope housing If you notice smoke or odors coming fro...

Страница 4: ...when working on computer Supports microSDHC card up to 32GB Driver free download for Windows XP SP2 Vista Win7 8 and Mac OS 10 5 10 9 direct plug in driver installation not required Rechargeable lithium battery Included Accessories 4 AC adapter PortableCaptureHD Software CD Quick Start Guide User Guide Calibration chart Cleaning cloth HDMI cable Rechargeable battery USB cable Video cable QSG Manua...

Страница 5: ...nt knob 4 Objective lens 5 Object stage 6 Stage height adjustment knob 7 Stage position locking knob 8 Capture button 9 LED light brightness control 10 Magnification zoom 11 HDMI port 12 5V DC in 13 TV out 14 USB port 15 Battery compartment 16 Battery charging indicator 5 ...

Страница 6: ... the battery power is low the low power indicator on the lower right side of the panel will dim Image quality will degrade Connect the power adaptor and plug it in to recharge the battery Inserting a MicroSDHC Memory Card not included You must insert a microSDHC card not supplied to record and store your pictures and videos 1 Turn off the microscope 2 Insert the card into the microSDHC card slot g...

Страница 7: ...ject in place 4 Rotate the stage height adjustment knob to raise or lower the stage 5 To lock the stage position firmly hold the stage height adjustment knob with one hand With the other hand rotate the locking knob toward you 6 Turn the LED light brightness control wheel to turn on and adjust the light 7 Select the degree of magnification by sliding the magnification zoom control up and down The ...

Страница 8: ...se Mass Storage to view captured images 3 To preview images on the computer choose PC Camera Run the PortableCaptureHD software Please refer to the PortableCaptureHD software user guide Note When working on a computer the unit s button functions are no longer operable and must be accessed via the PortableCaptureHD software The maximum image size for video is 720P and 1280 x 720 for stills 8 ...

Страница 9: ...le connection does not support video recording Video recording only can be performed without a TV connection For more details about HDTV connections via HDMI USB Video please refer to your HDTV manual Image Video Capture 1 Press the Back Playback button to switch between still photo mode and video mode 2 Press the Capture button to take a photo or to start recording video 3 Press the Capture butto...

Страница 10: ...enu Settings button to enter the submenu 2 Select Delete Current or Delete All 3 Confirm deletion by pressing OK Protect 1 In the playback mode press the Menu Settings button to enter the submenu 2 Choose from Lock options to lock and protect pictures from deletion 3 Confirm by pressing OK 10 Slide Show 1 In the playback mode press the Menu Settings button to enter the submenu 2 Select the interva...

Страница 11: ...se Mass Storage to view stored photos videos They are saved in DCIM Menu Settings 1 Press the Back Playback button to enter the main menu NOTE The main menu consists of 2 screens Menu 1 and Menu 2 To access to Menu 2 press the Back Playback button again 2 Press the Down button to scroll through your choices 3 When your setting choice is highlighted press the OK button 11 Main Menu 1 Main Menu 2 ...

Страница 12: ...hted press the OK button Set Resolution 1 Select a resolution from options WVGA 2M 3M 5M 8M 14M 2 Press OK to confirm Time lapse Still Capture You can set the device to take images ranging from 2 to 999 images over a defined time period From menu 1 choose Time lapse Capture and press the OK button Note To avoid premature battery power drainage use the AC adaptor 12 Main Menu 1 ...

Страница 13: ...entation time 2 Once you have set your number of images and interval press the OK button to confirm 3 Press the Back button to return to the streaming image 4 Press the Capture button to start the time lapse 5 Once all frames have been taken in the Time Lapse mode the microscope will revert back to the normal preview mode Note The Auto Power Off time needs to be set to a number higher than the set...

Страница 14: ...wn button to choose Strong Normal or soft 3 Press OK 14 Exposure Brightness 1 Select the value by pressing the Down button 2 Confirm choice by pressing the OK button Date Stamp 1 From menu 1 use the Down button to choose Date Stamp and then press OK 2 Choose Off Date only or Date Time 3 Press OK ...

Страница 15: ...d time by using the Up Down and Back buttons 2 You can select from among 3 formats YY MM DD DD MM YY and MM DD YY 3 Press OK Main Menu 2 Auto Power Off Set the unit to turn off automatically after a period of inactivity The default setting is Off this will keep your device on until you manually turn it off Use the Up and Down buttons to choose to have the unit automatically turn off after 3 minute...

Страница 16: ...ate frequency for your region 50Hz or 60Hz Format microSDHC Card 1 Insert your microSDHC Card 2 Choose Format from the main menu 2 settings 3 Choose SD Card Note All previously stored files on the card will be deleted after card formatting Note Please use microSDHC Class C6 C10 card for video recording A lower speed card may result in image lag for fast moving objects For still image capture a low...

Страница 17: ...refully with a soft fabric Microscope is connected to a television but no image appears on the television screen Ensure that the television is on Switch to the appropriate video input channel on your television Ensure that the HDMI video cable is securely connected to the microscope port and plugged into the correct input port on your television Cannot preview image from USB link to HDTV HDTV with...

Страница 18: ...asurement By software PortableCaptureHD bundled System requirements Vista Win7 8 and Mac OS 10 5 10 9 direct plug in driver installation not required Driver free download for Windows XP SP2 Size 5 9 x 4 x 8 9 149 x 104 x 227mm Weight 1 71 lbs 780g with battery Distributed by C A Marketing Inc 114 Tived Lane East Edison NJ 08837 USA Europe C A Europe 167 Hermitage Road Crusader Industrial Estate Lo...

Отзывы: