11
R50 Blue Bar
5101171 Rev. L
5. Connect a ground wire to the ground terminal of the power supply. (See
Figure 12
for ground terminal location)
6. Mount the neutralizing bar using the hardware provided with the
shipment. Refer to R50 Blue Bar installation instructions in Section 4 for
details.
7. Proceed to section on attaching high voltage cable to “D” and TrueAC.
8. Plug line cord into receptacle to energize power supply.
SLCC High Voltage Connector Assembly
The equipment you have ordered may be supplied with a spring-loaded connector
installed. If so, keep these instructions for use when ordering a replacement connector.
If the spring-loaded connector is not installed, follow the instructions below, using
Figure 8
as a guide.
1. Slide knurled plug (knurled end first) over the end of the cable that will be inserted
into the power supply.
2. Slide connector body (end without setscrew hole first) over cable.
3. Slide high voltage connector (small metal piece with threaded hole for
setscrew) over gold tip at end of connector wire. Line up setscrew hole in connector
body with hole in high voltage connector.
4. Insert setscrew in connector through the hole in the connector body and
tighten until setscrew is just even with or slightly below the surface of the connector
body.
5. Pull firmly to be sure high voltage connector is tight on conductor wire.
6. Turn contact spring (end with close turns) clockwise, by hand, onto high
voltage connector until spring butts against connector body.
Attaching High Voltage Cable to “D” and TrueAC Power Supply
1. Switch off power supply and unplug line cord from receptacle.
2. Insert SLCC high voltage connector in female port on the power supply and finger-
tighten (see
Figure 13
for TrueAC).
3. For “D” connect ground wire to ground terminal of power supply. For TrueAC,
connect shield wire to shield terminal of power supply (see
Figures 12
and
13
)
Removing High Voltage cable from “D” and TrueAC Power Supplies
1. Switch off power supply and unplug line cord from receptacle.
2. For “D” remove ground wire of cable assembly from ground terminal. For TrueAC,
remove shield wire of cable assembly from shield terminal (see
Figure 13
).
3. Carefully finger-loosen SLCC connector and remove cable from power
supply.