Mechanical Specifications - Tamp System
Category
Nominal
Minimum
Maximum
Incoming Air Pressure
60 - 100 PSI
40 PSI
125 PSI
Tamp Cylinder Pressure
30 - 50 PSI
20 PSI
80 PSI
Vacuum/Blow Pressure
30 - 60 PSI
20 PSI
80 PSI
Tamp Stroke
(10 in. cylinder)
3 - 9 in.
76 -228 mm.
3 in.
76 mm.
9.5 in.
241.3 mm.
Tamp Stroke
(20 in. cylinder)
3 - 19 in.
76-482 mm.
3 in.
76 mm.
19.5 in.
495.3 mm.
Air Consumption while
running
2.5 CFM at
80 PSI
2.0 CFM at
80 PSI
5 CFM at
80 PSI
Tamp-Blow Distance
(Pad to product blow
distance)
0.5 in.
12.7 mm.
0 in.
0 mm.
1.0 in.
25.4 mm.
Diagraph - an ITW Company PA/4600 & PA/6000 User Manual
Introduction
Page 5
Intr
oduction
1.6 System Dimensions
31in
.
23
in.
25
in
.
Содержание Diagraph PA/4600
Страница 1: ...PA 4600 PA 4600 PRINTER APPLICATOR PRINTER APPLICATOR PA 6000 PA 6000 4600 010 Revision G ...
Страница 47: ...Diagraph an ITW Company PA 4600 PA 6000 User Manual Maintenance Page 46 Maintenance ...
Страница 48: ...Diagraph an ITW Company PA 4600 PA 6000 User Manual Maintenance Page 47 Maintenance ...
Страница 49: ...Diagraph an ITW Company PA 4600 PA 6000 User Manual Maintenance Page 48 Maintenance ...