background image

 

The machine should be connected using the power cable supplied with the 
equipment. The connection is not intended for fixed cabling.  
This appliance uses flammable refrigerant (propane),  stored  in  the unit's 
refrigeration circuit. 
For this reason, the following precautions should be followed: 

  Maintain without obstruction the openings intended for ventilation of 

the enclosure of the appliance or of the recess. 

  Do not use mechanical devices or other means to accelerate defrosting, 

using only those recommended by the manufacturer. 

  Do not damage the refrigeration circuit. 

  Do not use electrical devices inside the food compartments unless they 

have been approved by the manufacturer. 

  Explosive substances, such as aerosols with flammable propellant, 

should not be stored in this machine.

 

In case of refrigerant leakage: 

  Do not generate any flame in the vicinity of the appliance. 

  Do not operate on/off switches or plug/unplug power cables in the 

vicinity of the appliance. 

  Do not use a direct flame. 

  Ventilate the area around the appliance immediately by opening doors 

and windows. 

  Notify an authorized service technician. 

In order to assure the proper operation and efficiency of this equipment, it 
is  of  paramount  importance  to  follow  the  recommendations  of  the 
manufacturer,  SPECIALLY  THOSE  RELATED  TO  CLEANING  AND 
MAINTENANCE  OPERATIONS,  which  should  be  performed  mostly  by 
qualified personnel only.

 

CAUTION: 

Do not try to perform repairs. The intervention of non-qualified personnel, 
besides of being dangerous, could result in serious malfunctioning. In case 

IT IS MANDATORY TO GROUND THE EQUIPMENT  

To avoid possible discharges on individuals or damages to the 

equipment, the machine should be grounded pursuant local 

and/or national regulations as the case may be. 

THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE 
OF DAMAGES ARISING DUE TO THE LACK OF THE GROUND 

INSTALLATION. 

SEE SECTION 4 OF THIS MANUAL 

 

 

Содержание NG R290

Страница 1: ...formed by qualified and certified professional personnel only Any use by the ice maker not intended to produce ice using drinking water is considered inappropriate It is extremely dangerous to modify or intend to modify this machine and shall make any type warranty void This device is not intended for use by persons including children whose physical sensory or mental capacities are limited or who ...

Страница 2: ...icinity of the appliance Do not operate on off switches or plug unplug power cables in the vicinity of the appliance Do not use a direct flame Ventilate the area around the appliance immediately by opening doors and windows Notify an authorized service technician In order to assure the proper operation and efficiency of this equipment it is of paramount importance to follow the recommendations of ...

Страница 3: ...s the previous one Nameplate On the back of the machine Check that in interior of the machine the installation kit is complete and comprises Ice scraper gas pipe 22 mm 0 86 inches discharge hose two filters and manual INSTALLATION EMPLACEMENT GUIDELINES An incorrect installation of the equipment may cause damages to individuals animals or other materials being the manufacturer not responsible for ...

Страница 4: ...rough the grids and this air has to go to the environment and not accumulate This is particularly important with the air ejected from the back of the machines you must leave a space to the wall of a minimum 10 cm allowing air to flow from behind and with an exit so that there is a renewal of the same avoiding the formation of hot air pockets in this area that could reduce the ice production of the...

Страница 5: ...the machine level at 150 mm 5 91 inches minimum It is convenient that the drainage pipe is of 30 mm 1 18 in of interior diameter and with a minimum gradient of 3 cm 1 18 in per meter see figure Electrical Connection Caution The positioning of the device must ensure that the power connection is not damaged or pinched Do not install multiple portable power outlet strips or other portable power suppl...

Страница 6: ...tions temperatures water quality etc proceed as follows 1 Connect to drinking water network Open the water inlet Verify the existence of leakages 2 Open the door and remove the protection elements that are inserted on the curtain 3 Connect the machine to the electrical network 4 Verify that there are no vibrations or frictions on the elements 5 Verify that the curtain moves freely 6 The machine ha...

Страница 7: ...the faucet 3 Disconnect the water inlet and outlet from the condenser 4 Prepare a solution at the 50 of phosphoric acid and distilled or demineralized water 5 Make the solution circulate through the condenser The solution is more effective if hot between 35ºC 95ºF and 40ºC 104ºF DO NOT USE HYDROCHLORIC ACID Air Condenser 1 Disconnect the machine 2 Disconnect the water inlet or close the faucet 3 C...

Страница 8: ...r Leak Control When working on the machine always check the water connections status of the clamps and hoses with the purpose of avoiding leakages and prevent damages or floods WATER QUALITY WARRANTY In areas with water hardness outside the range of 15ºF to 40ºF water filters or descaling systems are required to protect the ice machine The Warranty will cease to exist if the mentioned protective m...