7
ENGLISH
5. DRAINAGE
Drainage should be located lower than the output of the machine, at 5.9” (150mm) minimum.
It is convenient that the drain hose is 1.18” (30mm) inside diameter and with a minimum gradient of 0.36”/
ft (3cm/m), see figure.
6. ELECTRICAL CONNECTION
It is mandatory to ground the equipment. To avoid possible electric shock to individuals or damages to the
equipment, the machine should be grounded pursuant to local and/or national regulations as the case may
be.
The manufacturer shall be held harmless in case of damages arising due to the lack of the ground installation.
In case the supply cable is damaged, it should be replaced by a cable or special assembly to be furnished
by the manufacturer or after-sales service. Such replacement should be performed by qualified technical
service only.
The machine should be placed in such a way as to allow a minimum space between the back and the wall to
allow an easy access and without risks to the cable plug.
Regarding the electrical socket, Please allow ample room to install adequate switches and fuses.
Voltage is indicated in the nameplate and on the technical specifications of this manual. Variation in voltage
above the 10% stated on the nameplate could result in damages or prevent the machine start-up.
CORRECT
INCORRECT
INCORRECT
DRAIN LINE
DRAIN
DISPENSER
DISPENSER
DISPENSER
DRAIN
DRAIN
Содержание DHD 200-30
Страница 1: ...USER MANUAL MANUAL DEL UTILIZADOR MODELS MODELOS DHD 200 30 DHD 200 30 W ENGLISH ...
Страница 2: ...USER MANUAL MANUAL DEL UTILIZADOR ...
Страница 15: ...135 ...
Страница 16: ...136 ...
Страница 17: ...C 6872 25 C 13 ...