16. Check the bearings. If they feel rough when turning by hand, replace the bearings. Remove bear-
ings (36 & 117) from the shaft (38) using a hydraulic press.
17. If your pump is supplied with a shaft sleeve (24), the sleeve is locked in place with a roll pin (101)
and an a ring (104) to prevent leakage under the shaft. To remove shaft sleeve, push the roll pin
into the shaft (shaft has a drilled through hole) and pull the sleeve from the shaft along with the "0"
ring. Push the roll pin out of the shaft. Pump with slotted shaft sleeve, pull the sleeve along with "0"
Ring from the shaft. If roll pin is damaged, pull Roll pin out of shaft. Replace shaft sleeve, "0" Ring
and Roll pin if necessary.
Check "0" ring and shaft sleeve. If damaged, replace as necessary.
When reinstalling the sleeve onto the shaft, make sure that the roll pin is installed flush or
max. .005" under the sleeve O.D.
Follow the above procedure in reverse to reassemble the pump.
NOTICE:
1.
Make sure all gaskets, "0" rings, and sealing surfaces of the check valve are in good
condition before reassembly. Replace as is necessary.
2.
Make a heavy bead of "GASKET ELIMINATOR" loctite #518 or equivalent all around
the outer edge, inner edge and around the mounting holes on the wear plate (89) be-
fore reinstalling wear plate onto the pump casing (1) for sealing.
Inspect all gasket / o-ring / sealing surfaces before reassembly.
6.6 Preassembly inspections
6.6.1 Replacement guidelines
Casing check and replacement
WARNING:
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Inspect and ensure
gasket sealing surfaces are not damaged and repair or replace as necessary.
Gaskets, O-rings, and seats replacement
WARNING:
Risk of death or serious injury. Leaking fluid can cause fire and/or burns. Replace all gaskets
and O-rings at each overhaul or disassembly.
WARNING:
Risk of serious personal injury or property damage. Fasteners such as bolts and nuts are criti-
cal to the safe and reliable operation of the product. Ensure appropriate use of fasteners during
installation or reassembly of the unit.
•
Use fasteners of the proper size and material only.
•
Replace all corroded fasteners.
•
Ensure that all fasteners are properly tightened and that there are no missing fasteners.
6.6 Preassembly inspections