4 Installation
4.1 Pre-installation
Precautions
WARNING:
•
When installing in a potentially explosive environment, ensure that the motor is properly
certified.
•
All equipment being installed must be properly grounded to prevent unexpected dis-
charge. Discharge can cause equipment damage, electric shock, and result in serious in-
jury. Test the ground lead to verify it is connected correctly.
NOTICE:
•
Electrical connections must be made by certified electricians in compliance with all inter-
national, national, state and local regulations.
•
Supervision by an authorized ITT representative is recommended to ensure proper instal-
lation. Improper installation may result in equipment damage or decreased performance.
4.1.1 Pump location guidelines
4.1.2 Foundation requirements
Requirements
•
Provide a flat, substantial concrete foundation in order to prevent strain and distortion when you
tighten the foundation bolts.
4.1.3 Baseplate-mounting procedures
4.1.3.1 Prepare the baseplate for mounting
1.
Remove all the attached equipment from the baseplate.
2.
Clean the underside of the baseplate completely.
3.
If applicable, coat the underside of the baseplate with an epoxy primer.
Use an epoxy primer only if using an epoxy-based grout.
4.
Remove the rust-proofing coat from the machined mounting pads using an appropriate solvent.
5.
Remove water and debris from the foundation-bolt holes.
4.1.3.2 Install the baseplate using shims or wedges
Required tools:
•
Two sets of shims or wedges for each foundation bolt
•
Two machinist's levels
•
Baseplate-leveling worksheet
1.
If you use sleeve-type bolts, fill the bolt sleeves with packing material or rags to prevent grout from
entering the bolt holes.