11. Install the O-ring (412F) around the liner lip and install suction cover with cap screws (370E) and
washers (528K). Check for free rotation by turning impeller clockwise by hand with wrench on im-
peller screw.
12. When connecting electrical service, make sure polarity is correct to give counterclockwise rotation
when looking into the suction opening.
Table 1: Typical Parts List
Item
Qty / Pump
Part Name
100
1
Casing
100B *
1
Liner, Suction Cover
101 *
1
Impeller
182
1
Suction Cover
199
1
Washer. Impeller
330 *
1 set
Shim, Impeller
340
1
Motor Mount
370C
1
Hex Cap Screw, Impeller
370E
varies
Hex Cap Screw
370J
varies
Hex Cap Screw
370K
varies
Hex Cap Screw
412F *
1
O-ring
496 *
1
O-ring
528K
varies
Washer
9700
1
Motor
* Recommended spare parts, including outer mechanical seal for motor.
5.4 Reassembly
JCU Installation, Operation, and Maintenance Manual