NOTICE:
Remove all dirt from the mounting pads in order to ensure that the correct leveling is achieved.
Failure to do so can result in equipment damage or decreased performance.
a) Put one machinist's level lengthwise on one of the two pads.
b) Put the other level across the center of the two pads.
c)
Level the pads by adjusting the four jackscrews in the corners.
Make sure that the machinist's level readings are as close to zero as possible, both lengthwise and
across.
6.
Hand-tighten the nuts for the foundation bolts.
7.
Check that the driver's mounting pads are level and adjust the jackscrews and the foundation bolts
if necessary.
The correct level measurement is a maximum of 0.167 mm/m | 0.002 in./ft .
The maximum variation from one side of the baseplate to the other is 0.38 mm | 0.015 in.
4.3 Install the pump, driver, and coupling
1.
Mount and fasten the pump on the baseplate. Use applicable bolts.
2.
Mount the driver on the baseplate. Use applicable bolts and hand tighten.
3.
Install the coupling.
See the installation instructions from the coupling manufacturer.
4.4 Pump-to-driver alignment
Precautions
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
Alignment methods
Three common alignment methods are used:
•
Dial indicator
•
Reverse dial indicator
•
Laser
Follow the instructions from the equipment manufacturer when you use the reverse dial indicator or laser
methods. Detailed instructions for using the dial indicator method are contained in this chapter.
4.3 Install the pump, driver, and coupling
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
23
Содержание Goulds Pumps 3700
Страница 2: ......