Item Description
1.
Shims
Figure 15: Example of incorrect vertical alignment (side view)
4.
Repeat the previous steps until the permitted reading value is achieved.
NOTICE:
The specified permitted reading values are valid only at operating temperature. For cold set-
tings, other values are permitted. The correct tolerances must be used. Failure to do so can
result in misalignment. Contact ITT for further information.
4.4.8 Perform parallel alignment for a horizontal correction
Refer to the alignment table in "Permitted indicator values for alignment checks" (see Table of Contents
for location of table) for the proper cold alignment value based on the driver temperature rise and the
pump operating temperature.
A unit is in parallel alignment when the parallel indicator (P) does not vary by more than 0.05 mm |
0.002 in. as measured at four points 90° apart at the operating temperature.
1.
Set the parallel alignment indicator (P) to zero on the left side of the driver coupling half (Y), 90°
from the top-center position (9 o’clock).
2.
Rotate the indicator through the top-center position to the right side, 180° from the start position
(3 o’clock).
3.
Record the indicator reading.
When the reading value is... Then...
Negative
The driver coupling half (Y) is to the left of the pump coupling half (X).
Positive
The driver coupling half (Y) is to the right of the pump coupling half (X).
4.
Slide the driver carefully in the appropriate direction.
NOTICE:
Make sure to slide the driver evenly. Failure to do so can negatively affect horizontal angular
correction.
Y X
Figure 16: Example of incorrect horizontal alignment (top view)
4.4 Pump-to-driver alignment
30
Model 3600 i-FRAME API610 11th Edition / ISO 13709 2nd Edition to current API BB3 Multi-Stage, Axially Split Installa-
tion, Operation, and Maintenance Manual