Figure 18: Spring mounted baseplate
NOTICE:
The foundation pads are supplied by the customer. They are to be 16-20 micro-inch surface
finish 316 stainless steel plate.
7.
Level the baseplate while making final height adjustments. Adjust the baseplate height by loosening
the top jam nut and adjusting nut. Change the height by moving the lower adjusting nut. When the
baseplate is level, tighten the top adjusting nuts just enough to make sure the top springs are not
loose in their followers and then snug the lower and upper jam nuts.
NOTICE:
Suction and discharge piping must be individually supported. The spring mounted baseplates
are designed to support piping loads developed by thermal expansion only.
3.9 Spring mounted baseplates