251
113A/551F
134
358V
Figure 26: Oiler assembly
1.
Remove the vent assembly from the top of the bearing housing.
2.
Remove the pipe plug from the bottom of the bearing housing.
3.
Unscrew and remove the reservoir.
4.
Flush the oiler and bearing housing with a light grade of oil until all foreign particles are removed.
5.
Screw the pipe plug and vent assembly back into place.
6.
Fill the reservoir with a good grade of filtered mineral oil.
NOTICE:
Make sure to fill the oiler and bearing housing with oil through the oiler reservoir.
7.
Place your thumb over the reservoir spout, invert the reservoir, and place it onto the lower casting
while removing your thumb.
Allow the reservoir to empty as it fills the bearing housing. You will need to fill the reservoir several
times before the correct level is reached.
When the correct oil level is reached, no more oil will run out of the reservoir.
A periodic filling of the reservoir is required. When the oil becomes dirty, repeat this procedure.
6.3.2.1 Lubricating-oil requirements
Oil specifications
Use oils that meet these specifications. These oils are furnished by all major oil companies. It is the re-
sponsibility of the oil vendor to supply a suitable lubricant.
Do not mix oils from different suppliers.
Specification
Requirement
Saybolt viscosity at 38°C | 100°F 215 SSU – 240 SSU
Saybolt viscosity at 99°C | 210°F 49 SSU
Viscosity index, minimum
95
API gravity
28–33
Pour point, maximum
-6.7°C | +20°F
Flash point, minimum
204°C | 400°F
Additives
Rust and oxidation inhibitors
ISO viscosity
46
6.3 Bearing maintenance
40