2
1
1.
Stabilizer bar, 18–24 in. (46–61 cm)
2.
Alignment rods
Figure 38: Stabilizer bar and alignment rods
2.
Disconnect the seal water lines at the stuffing boxes and remove the gland bolts.
3.
Remove the dowel pins and all parting line bolts except for the two upper most and two lower most.
2
1
1.
Upper most bolts
2.
Lower most bolts
Figure 39: Dowel pin and parting line bolts
4.
Install alignment rods through the upper half and into the tapped bottom half, one on the suction
side and one on the discharge side above the horizontal center line of the casing.
An alignment rod is a threaded rod that screws into the bottom half of the casing and is approxi-
mately 2 in. (5 cm) longer than one half of the impeller diameter. This prevents the top half from
falling onto the impeller and also helps with alignment while installing the upper half. If alignment
rods are not supplied with the pump, then they can be made from a threaded rod.
5.
Place nylon slings around upper-half casing ears and pull the slings taut so that they cannot slip off.
6.8 Vertical units
54
Model 3409 Installation, Operation, and Maintenance Manual