Model
Size (mm)
English units
Metric units
5x6-11 (125)
30x3.5
280
559
379
758
6x8-13 (150)
36x4
488
976
662
1324
Mark casings as shown below and apply torque values in this sequence or as noted in the instructions
below.
NOTICE:
Check torqueing tools to ensure the calibration dates are current; the use of an impact wrench
is not allowed for torqueing hardware.
1.
Using a cross bolt pattern as noted in the figures above, carefully mate the components in the liquid
end stack to ensure proper metal to metal contact of the assembly.
2.
Use tie bolts nuts 1 thru 4 as shown.
3.
Bring nuts up evenly by hand with a wrench
4.
Snug nuts with wrench by hand to approx. 20 to 30 ft-lb.
5.
Mount suction and discharge casing feet in final location.
6.
Place liquid end assembly horizontally on a milled surface (the baseplate supplied with the pump
can be used).
7.
Check flatness of casing feet against the milled surface with a feeler gauge. If not flat, carefully and
evenly loosen the four tie bolt nuts just enough to allow the casing feet to be moved so they are flat
on the milled surface of the table. Variation is to be ≤ 0.003 in. If greater than 0.003 in, reface to
meet requirements or replace casing feet.
8.
Once the feet are flat on the table, retighten tie rod nuts 1 thru 4 in the manner defined above.
9.
Tighten tie rod nuts 5 thru 8 in the same manner.
10. Tighten all eight tie rod nuts in sequence shown in Figure above by hand with torque wrench to ap-
proximately 50 ft-lb.
11. Mount dial indicators to shaft, measure and record the bearing housing face run-out on the suction
and discharge casings (see sketch below). If any readings exceed 0.005 in, stop and address the
issue. Note: Because there are no bearings mounted at this time, the shaft will need to be pushed
inward from the discharge end until it stops. Set the gauges to zero and record the readings every
90
o
.
9.4 Tie-Rod Torque Specifications and Procedure
Model 3393 Installation, Operation, and Maintenance Manual
121
Содержание GOULDS PUMPS 3393
Страница 1: ...Installation Operation and Maintenance Manual Model 3393 ...
Страница 2: ......
Страница 67: ...6 5 Disassembly Model 3393 Installation Operation and Maintenance Manual 65 ...
Страница 69: ...6 5 Disassembly Model 3393 Installation Operation and Maintenance Manual 67 ...
Страница 73: ...6 5 Disassembly Model 3393 Installation Operation and Maintenance Manual 71 ...
Страница 76: ...6 5 Disassembly 74 Model 3393 Installation Operation and Maintenance Manual ...
Страница 77: ...6 5 Disassembly Model 3393 Installation Operation and Maintenance Manual 75 ...
Страница 78: ...6 5 Disassembly 76 Model 3393 Installation Operation and Maintenance Manual ...
Страница 81: ...6 5 Disassembly Model 3393 Installation Operation and Maintenance Manual 79 ...
Страница 82: ...6 5 Disassembly 80 Model 3393 Installation Operation and Maintenance Manual ...
Страница 92: ...6 7 Reassembly 90 Model 3393 Installation Operation and Maintenance Manual ...
Страница 97: ...6 7 Reassembly Model 3393 Installation Operation and Maintenance Manual 95 ...
Страница 100: ...6 7 Reassembly 98 Model 3393 Installation Operation and Maintenance Manual ...
Страница 101: ...6 7 Reassembly Model 3393 Installation Operation and Maintenance Manual 99 ...