Preparation for Installation:

Assemble the parts and tools required:

• Autocirc

®

 pump package includes the pump with a built-in timer, a 6ft. cord, and 

wall mounting bracket.

• Two stainless steel flexible hoses (1/2” x 3/8”) - length as required. (sold separately)

• Adjustable wrench and screwdriver.

• Select the sink under which the Autocirc

®

 pump is to be located (the sink where 

hot water takes longest to arrive).

Australia

This pump must be installed in accordance with AS3500.

U.L. Caution

This pump has been tested using water only. Its suitability for use with liquids other than  

water is the end user’s responsibility.

Installation

Step 1

If not already available, install a 115 Volt/ 60Hz 

outlet within six (6) feet of the installation site (the 

faucet/tap farthest from the water heater), as the 

Autocirc is supplied with a 6 ft. long, grounded 

cord. The Autocirc pump requires only 14 watts and 

0.3 amps of power (see Fig. 1).

Step 2

Fasten the Autocirc to the wall under the sink using 

the wall bracket provided in the Autocirc kit. Be sure 

the pump timer is turned toward the front and is 

accessible for setting and changing the time (see 

Fig. 2). The pump must be installed only in a vertical 
position as shown.

Step 3

Close the under sink hot and cold water riser 

shut-off valves and open the hot and cold water 

faucets/taps to relieve the water pressure. Close the 

water faucets/taps.

 

Note: in some older homes, the riser shut-off valves 

may be difficult to shut off completely. If this is the 

case turn the water off at the main water inlet valve 

to the house.

Remove the existing flexible line connection to the hot 
and cold water faucet/tap threaded nipples (see Fig. 3).

CAUTION: Do Not fasten pump to a thin wood panel 

wall as this might create a vibration noise when the 

pump is operating.

Figure 1

Figure 2

Figure 3

Содержание E1-BCANCT1W-06

Страница 1: ...reference Laing Thermotech Instruction Manual 6 71 075 004 Models E1 BCANCT1W 06 and E1 BCANRT1W INSTALLER PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE Autocirc The Instant Hot Water Pump Save Water...

Страница 2: ...F automatically when water temperature reaches 95 F 35 C ensuring instant availability of shower warm water with maximum temperature hot water only seconds behind When the pump is OFF a built in auto...

Страница 3: ...ed with a 6 ft long grounded cord The Autocirc pump requires only 14 watts and 0 3 amps of power see Fig 1 Step 2 Fasten the Autocirc to the wall under the sink using the wall bracket provided in the...

Страница 4: ...the corresponding faucet tap Be sure the hot side connection hose is attached to the hot water faucet tap and the cold water side connection is attached to the cold water faucet tap Be sure the hoses...

Страница 5: ...ON position In the ON position the pump runs automatically whenever the built in thermostat senses the requirement for hot water In the OFF position the pump does not operate at any time In either th...

Страница 6: ...main hot water supply line will take longer for the hot water to arrive however usually faster than before installing the Autocirc I am away from my home for extended periods of time 2 weeks or more Y...

Страница 7: ...tors supplying the pump Connect the ground wire to the ground terminal in the wiring compartment Failure to follow these instructions could result in serious personal injury death and or property dama...

Страница 8: ...ult in serious personal injury death and or property damage WARNING Electrical Shock Hazard Be certain the electrical power is not present at the motor leads before continuing Failure to follow these...

Отзывы: