background image

CGW-I

April 2009

   

Installation and 
Operation Guide 

Version 3.18 Release 1

Содержание CGW-I

Страница 1: ...CGW I April 2009 Installation and Operation Guide Version 3 18 Release 1...

Страница 2: ...CGW I Cellular Gateway BRI GSM Interface Installation and Operation Manual VERSION 3 18 ED 1 APRIL 2009...

Страница 3: ...render this publication invalid WARRANTY In the event this product proves to be defective in workmanship or materials within a period of one year from date of shipment ITS will repair or replace the p...

Страница 4: ...phone Interface with NT Card for CGW I Synchronization 8 PBX NT CGW 9 External Synchronization Feature 10 2 5 Installation 10 Hanging Up the CGW I 10 SIM Card Insertion 11 Connecting to the CGW I 12 T...

Страница 5: ...oll Restrictions 30 Channel Settings 32 Adjusting the Volume Gain Level 33 Operation System Parameters 34 Application System Parameters 35 Prepaid Settings 39 Controlling the CGW I 41 3 5 Report Menu...

Страница 6: ...e installation setup and operation of your new Cellular GateWay for ISDN BRI interface which we will now simply refer to as the CGW I throughout this manual It is intended for System Installers and Ad...

Страница 7: ...when SIM is busy Toll Restrictions Define which cellular operator prefixes to allow the CGW I to call and which ones not to allow Redirect Call Override Toll Restrictions and setup a cross network co...

Страница 8: ...Allow calls to automatically connect to the strongest available signal or restrict them to a specific network operator Dialing Mode Support Overlap or En Block End of Dialing Digit Reduce the time req...

Страница 9: ...ts The following table describes the contents of your device package Note Should the package be damaged or should items from the packing list be missing contact your distributor directly Table 1 Conte...

Страница 10: ...ox of which the height is 215mm depth 125mm and width 42mm Antenna Connectors Liquid Crystal Display LAN LI ACT Indicators RS 232 Connector Cellular Engine Indicators Sync In Connector ISDN Connector...

Страница 11: ...the SIM must be disabled to complete the initial installation You can disable the SIM with any GSM mobile phone If you enable the PIN after installation using your mobile phone you must enter the PIN...

Страница 12: ...the calling prefix then routed to the correct interface If the prefix is landline it creates a connection for the call to leave via the PSTN interface If the prefix is cellular it routes the call to t...

Страница 13: ...NT This diagram describes an ISDN Extension CGW I configuration option which can be used when the PBX requires a single source clock and the PBX has an NT interface to an extension telephone or termin...

Страница 14: ...PBX requires a special NT card to create an additional NT interface leaving the PBX which will provide the source clock By connecting the new PBX NT interface to the Synch In interface of the CGW the...

Страница 15: ...es from the NT source When this feature is disabled the CGW I becomes the Master of the time clock it sends to the PBX You should also disable External Synchronization when the CGW I connects to a TE...

Страница 16: ...9V adapter from the electric power outlet when inserting or removing the SIM card The figure above can be used as guideline for the following steps 1 Hold the device in your hands with the display poi...

Страница 17: ...lide it in with the SIM card contacts facing up Connecting to the CGW I n Screw in the antenna cable s to the antenna to the Ant 1 or Ant 2 connector 1 Note If you are only using one SIM card make sur...

Страница 18: ...CGW I Cellular Gateway BRI GSM Installation and Operation Manual 13 RJ 45 Cable The following diagram shows how to connect the different cables to your device 2 3 4 5 PC NT 9VDC 1 5A Power Supply PBX...

Страница 19: ...e over a LAN once you have completed steps 1 5 you must remove the RS 232 cable and connect an RJ 45 Cable from your LAN to the LAN interface of the CGW I Turning on Your CGW I CAUTION To avoid damage...

Страница 20: ...and both channels The number of the operator can be between 5 7 digits The reception level can be from 2 3 digits LCD Messages Description Action Version Number During power on the version number is...

Страница 21: ...d the 2 3 digit signal level are displayed Connected XXX When a call is connected Connect and the 2 3 digit signal level are displayed Disconnecting XXX When a call is being disconnected Disconnecting...

Страница 22: ...orming a Gentle Close on this channel Name is displayed when the Name value is selected in LCD Operator Display see page 29 Opr XXXXXXX Close The device is performing a Gentle Close on this channel Op...

Страница 23: ...ally 2 At the end of each stage of installation click the Next button to continue GUI Requirements CGW I Manager is designed to run on screens set to 1024 x 768 resolution Any other setting may not di...

Страница 24: ...n Function OK Saves any changes you have made and then closes this window Apply Sends the changes made on this window to your device but without closing the window If this is the first time you are se...

Страница 25: ...ed Print Prints the contents of the current configuration file Recent File Shows the most recently used configuration files Exit Closes the program View Menu The following table describes the differen...

Страница 26: ...ou can choose from the following connections COM Port Network or Modem To open the Communication Selection window From the Main menu select Communication Communication Selection COM Port The COM Port...

Страница 27: ...window Note Since you are connecting with a modem a phone number of the CGW I must be defined See the Device Selection section for more details on defining a modem 3 The CGW I modem s phone number ap...

Страница 28: ...he specific location To open the Device Selection window Click the Device button in the Communication Selection window Note If you select either Network or Modem to communicate with your CGW I the net...

Страница 29: ...ponsible for this device Representative Phone Phone number of the contact person responsible for this device To delete a device or folder 1 Select the folder or device you want to delete then click th...

Страница 30: ...ead parameters for the first time default 1234 during a connection to a specific CGW I device It is recommended that you change the password A gray bar will show the loading progress followed by a mes...

Страница 31: ...on was successful or not Setting a Password A password must be filled in before reading or sending parameters To change the administrator s password 1 Enter the Current Password Note Password is not c...

Страница 32: ...our CGW I device Enter the following parameters Field Parameter Connection Type Select the BRI interface NT or TE Operation Mode Select either FIX TEI or AUTO TEI When in AUTO TEI the TEI value is not...

Страница 33: ...isables the device s dial tone heard on an extension phone Call Duration Limitation Limits the length in minutes of outgoing calls to protect you from connections that are accidentally left open 15 90...

Страница 34: ...vice will wait between digits before dialing entered number EnBlock Minutes Digit Minimum number of digits in EnBlock for call initiation First Digit Timeout Number of seconds 1 60 device will wait be...

Страница 35: ...d up to 20 prefixes The Not Allowed list can hold up to 12 prefixes To allow a specific prefix to be used on a specific channel 1 Check the Allowed checkbox to enable both Allowed Prefix List panes Th...

Страница 36: ...played Note Prefixes should not conflict with any existing PBX LCR Rules 3 Enter dialing prefix then click OK The number is added to the Not Allowed Prefix List Editing a calling prefix 1 Click the pr...

Страница 37: ...times in the Channel Settings screen and are locked out by the SIM you must enter the PUK code to unlock the SIM Call your network operator to get the PUK code if you do not know it Roaming Enable to...

Страница 38: ...Channel 2 display the volume level of the different outgoing sound streams The Mobile to FIX fields Channel 1 and Channel 2 display the volume level of the different incoming sound streams 2 Click and...

Страница 39: ...is unable to handle varying incoming caller ID formats MSN Routing To Enter the default Multi Subscriber Number to route incoming calls made to this specific SIM s cellular number The MSN may be a spe...

Страница 40: ...he dial tone The Callback feature subscriber receives the dial tone and then the gateway performs call back returns a call to the subscriber When the DISA feature is enabled for a specific radio chann...

Страница 41: ...ored in the Links Database Links Table Your CGW I device can store up to 1 500 links between outgoing caller IDs and dialed numbers When a Direct Dial In DDI calls back your device recognizes the DDI...

Страница 42: ...CGW I Cellular Gateway BRI GSM Installation and Operation Manual 37...

Страница 43: ...h features Channel select the channel from combo box This defines a cellular channel where the subscriber can call to get Call Back and Call Through features It is possible to select Channel 1 Channel...

Страница 44: ...e network provider for the month for each SIM Range 1 9999 Prepaid Time Enter the number of monthly discounted minutes calling time threshold for each SIM card not including Free Time minutes The rema...

Страница 45: ...Day and Time to the current day and time Allow grace of When Gentle Blocking is selected in Disable Channel Method the number of minutes that a call which has exceeded the SIM s Prepaid Time credit a...

Страница 46: ...ts communications protocol between device and ISDN layers 1 2 and 3 Cellular Daily Restart Allows you to set a time for a daily cellular engine restart to be performed automatically by the unit for ea...

Страница 47: ...described in one of the following sections Properties The Properties window displays the specific manufacturing details of your CGW I device They are as follows Property Manufacturing Detail Device S...

Страница 48: ...e Accumulated Time will be logged as 36 seconds i e based on the use of 3 Time Units Bad Reception Level Counter Number of times that each SIM experiences a Bad Reception Level for more than FOUR cons...

Страница 49: ...up alerts see System Alarms section Remaining Prepaid SIM Time fields are explained in the following table SIM 1 SIM 2 When the Prepaid SIM Time field is enabled see System Operation screen page 34 t...

Страница 50: ...Channel To read the current CDR 1 Select Report CDR Read CDR The Read CDR Records window opens 2 Enter the name for the new CDR you want to create and click OK The file is saved in the default CGW I d...

Страница 51: ...what alarms the CGW I device should trigger and where to send notification Alarm notifications apply to the device and both SIM cards where applicable The following is a list of the different triggers...

Страница 52: ...are more than 90 full The following table lists the information required to send an SMS alert Field Parameter SMS Phone Number 1 Enter the first number to send an SMS notification SMS Phone Number 2...

Страница 53: ...ge 113 dBm weak to 51dbm hi If reception level is low the antenna location or type of cable may need to be improved Suggestions to improve antenna placement move close to window or to a higher floor p...

Страница 54: ...r Reset or Power Up Stopped Due to communication error HW Reset No Radio Engine Disable Sending SMS No SIM Time ISDN Channel Status States Displays one of the following ISDN channel states Idle Callin...

Страница 55: ...TMF Dialing France Germany 1TR6 Germany Dial Length Up to 5 digits operator services or emergency calls Up to 16 digits normal GSM operation Antenna Frequency 800 1900 MHz Antenna Maximum Power 2W Ant...

Страница 56: ...CGW I Cellular Gateway BRI GSM Installation and Operation Manual 51...

Отзывы: