background image

USER

 

MANUAL

 

V2.22

 

ITS

 

COMMANDER™

    

Model:

 

1RU8126MS

  

Page

 

19

 

User Interface Tabs 

Names and No

Ɵ

fi

ca

Ɵ

ons Tab 

Relays 

Labels

 

can

 

be

 

changed

 

in

 

the

 

[Names

 

and

 

No

fi

ca ons]

 

tab

 

Relays

 

are

 

grey

 

when

 

open,

 

they

 

are

 

green

 

when

 

closed

 

Clicking

 

the

 

[OPEN]

 

/

 

[CLOSE]

 

slider,

 

will

 

open

 

or

 

close

 

the

 

relay.

 

 

Opera

Ɵ

ng Parameters 

Current

 

and

 

Voltage

 

are

 

displayed

 

for

 

the

 

unit

 

Temperature

 

and

 

Humidity

 

are

 

displayed

 

when

 

sensors

 

are

 

connected,

 

units

 

of

 

measurement

 

can

 

be

 

changed

 

in

 

the

 

[Con

fi

gura on]

 

tab.

 

Will

 

turn

 

red

 

when

 

upper

 

threshold

 

is

 

exceeded,

 

and

 

blue

 

when

 

lower

 

thresholds

 

are

 

exceeded

 

.

  

Thresholds

 

may

 

be

 

changed

 

in

 

the

 

[Names

 

and

 

No

fi

ca ons]

 

tab.

 

Analog

 

1

 

and

 

Analog

 

2

 

voltages

 

are

 

displayed

 

when

 

connected

 

Network

 

me

 

and

 

date

 

are

 

displayed

 

when

 

con

fi

gured

 

in

 

a

 

network

 

System Parameters 

Displays

 

all

 

system

 

parameters.

 

Can

 

be

 

changed

 

in

 

the

 

[Con

fi

gura on]

 

tab

 

Summary Tab 

(con

Ɵ

nued)

 

The

 

[Names

 

and

 

No

fi

ca ons]

 

tab

 

allows

 

the

 

user

 

to

 

provide

 

meaningful

 

names

 

for:

  

 

Outlets

 

 

Relays

 

 

Inputs

 

 

Analog

 

Inputs

 

 

Power

 

 

This

 

tab

 

also

 

allows

 

the

 

user

 

to

 

set

 

the

 

types

 

of

 

no

fi

ca on

 

requested

 

(for

 

all),

 

alarm

 

state

 

(inputs

 

only),

 

and

 

Lower

 

/

 

Upper

 

Limits

 

(

 

Analog

 

and

 

Environmental

 

inputs).

 

 

Email

 

 

SNMP

 

Содержание 1RU8126MS

Страница 1: ...W ITSCOMMANDER COM Read this manual before using this product Failure to follow the instruc ons and safety precau ons in this manual can result in serious injury or death Keep this manual in a safe lo...

Страница 2: ...hern Manufacturing herea er referred to as EP shall not be held liable for any damage or injury involving its enclosures and or its remote power manager and monitoring system if used or operated in an...

Страница 3: ...fica ons 6 2 General Informa on Specifica ons 7 Features 8 3 Installa on Moun ng 9 Installa on 10 Set Up 11 4 User Interface Tabs Summary 18 Names and No fica ons 19 Scheduler 19 Unit Log 25 Configura...

Страница 4: ...g the capability to remotely control outlets to reboot equipment These features can reduce unnecessary trips to inspect or service the cabinet thereby saving money Southern Manufacturing s ITS Command...

Страница 5: ...the risk of serious injury or death and to ensure the con nued safe opera on of this product NOTE Notes provide addi onal informa on when comple ng a specific task or procedure Notes will be designat...

Страница 6: ...ar cular installa on If this equipment does cause harmful interference to radio or televi sion recep on which can be determined by turning the equipment o and on the user is en couraged to try to corr...

Страница 7: ...urrent 10 A Relay Connector 12 Posi on Screw Terminal 12 22 AWG Temperature Sensor Thermistor R 25 C 10k 1 4 1 feet 1 25m Humidity Sensor 26mV RH 3 RH Linear 3 3 V Supply Temperature Humidity Connecto...

Страница 8: ...tatus indicator Green labeled A through H 5 LCD Screen 6 Select Bu on 7 Ethernet Port ITEM DESCRIPTION Features 1 2 4 3 6 7 8 8 5 9 10 11 12 13 14 8 Adjustable rack moun ng ears 9 I O Expansion Port 1...

Страница 9: ...ket loca on 1 Remove retaining screws from unit body 2 Choose the loca on of the bracket by aligning the moun ng bracket holes to the unit body 3 Secure using retaining screws 4 Repeat for the other s...

Страница 10: ...the user interface Laptop PC etc 1 Connect an RJ45 patch cable to the ITS Commander Ethernet Port 2 Connect the other end of the RJ45 Patch cable to the network switch 3 User interface may be accessed...

Страница 11: ...serve as an ON OFF switch CAUTION Ensure input circuit breaker is in the OFF posi on before applying power to the unit CAUTION Do not remove the MALE end of the power cord in order to hardwire the un...

Страница 12: ...labeled A H indicate the ON OFF status of each outlet An illuminated LED means ON Relays 1 Connect desired equipment to the relay posi on using 12 22 AWG wire 2 Relay labels may be changed in the Name...

Страница 13: ...d NC contact closures may be changed in the Names and No fica ons tab 5 LEDs on the rear of the unit labeled Input 1 12 indicate the OPEN CLOSED status of each input An illuminated LED means a CLOSED...

Страница 14: ...ture probe to the following pins Pin 4 TEMP Pin 5 GND 2 Temperature threshold levels may be changed in the Names and No fica ons tab Analog Input 1 Connect desired equipment to the analog posi on usin...

Страница 15: ...s bar h p 192 168 0 50 2 When first accessing the user interface log in to the unit using the default log in informa on 3 To configure the unit select the Configura on User name admin Password its Sys...

Страница 16: ...s may cause the unit to lose network connec vity If connec vity is lost hold down the front panel bu on to restore the unit to its default se ngs Network Email SMS 1 Enter the desired Email address in...

Страница 17: ...o 3 Read and Write Communi es as desired 2 Select No fica ons Enabled if no fica ons traps are desired 3 Enter the Receiver IP address 4 Enter the community name Click Save Configura on to save change...

Страница 18: ...ica ons tab Dry contact inputs are green when in a non Alarm status Default Alarm status is a closed contact Dry contact inputs will turn red when in an Alarm status as set in the Names and No fica on...

Страница 19: ...Will turn red when upper threshold is exceeded and blue when lower thresholds are exceeded Thresholds may be changed in the Names and No fica ons tab Analog 1 and Analog 2 voltages are displayed when...

Страница 20: ...an email no fica on all state changes Select SNMP to receive a trap no fica on all state changes Names and No fica ons Tab con nued Inputs Input Labels can be changed for each outlet max 30 character...

Страница 21: ...ap no fica on threshold limits Enter the desired voltage hysteresis default 1 volt Environmental Set Lower and Upper threshold limits Temperature units may be changed in the configura on tab Select Em...

Страница 22: ...N Ac on taken during the event NEXT Lets the user know a er changes have been saved when the next scheduled ac on is to take place for that event Daily Recurring NAME Event label can be changed max 30...

Страница 23: ...Lets the user know a er changes have been saved when the next scheduled ac on is to take place for that event Weekly Recurring NAME Event label can be changed max 30 characters TIME Time for the desi...

Страница 24: ...o a ected ACTION Ac on taken during the event MONTHS Select months in which the event is to occur NEXT Lets the user know a er changes have been saved when the next scheduled ac on is to take place fo...

Страница 25: ...log entries are displayed Click NEXT to navigate trough further entries To download the log file Select the records start and stop date Unit Log NOTE An asterisk indicates a change in the status since...

Страница 26: ...ca on The configura on file may also be uploaded into a unit Items covered in the configura on file Schedule Names and No fica ons Configura on File To upload a configura on file 1 Click Choose File 2...

Страница 27: ...visit www ITSCOMMANDER com for firmware updates The Firmware tab allows the user to change the download firmware updates Please visit www ITSCOMMANDER com to download firmware updates for this unit To...

Страница 28: ...22 ITS COMMANDER Model 1RU8126MS Page 28 Technical Assistance NOTE Please visit www ITSCOMMANDER com for Q A and Technical Assistance You may also email us at contactus ITSCOMMANDER com or phone us a...

Страница 29: ...GE CAUSED BY IMPROPER INSTALLATION DAMAGE CAUSED BY A THE INSTALLER DAMAGE CAUSED BY ROADWAY TRAFFIC ACTS OF VANDALISM ACTS OF GOD NORMAL WEAR AND TEAR MODIFICATIONS OR ALTERATION OTHER THAN NORMAL MA...

Отзывы: