background image

USER

 

MANUAL

 

V2.22

 

ITS

 

COMMANDER™

    

Model:

 

1RU8126MS

  

Page

 

6

 

Cer

Ɵ

fi

ca

Ɵ

ons and Compliances 

NEMA

 

The

 

ITS

 

Commander™

  

is

 

designed,

 

tested

 

and

 

manufactured

 

to

 

meet

 

the

 

requirements

 

of

 

the

 

following

 

na onal

 

safety

 

standards:

 

FCC

  

Part

 

15

 

Class

 

B

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

of

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

  

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protec on

 

against

 

harmful

 

interference

 

in

 

a

 

residen al

 

installa on.

  

This

 

equipment

 

generates,

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instruc ons,

 

may

 

cause

 

harmful

 

interfer

ence

 

to

 

radio

 

communica ons.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

par cular

 

installa on.

  

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

televi

sion

 

recep on,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

o

ff 

and

 

on,

 

the

 

user

 

is

 

en

couraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

o

 

f

 

the

 

following

 

measures

 

(1)

 

Reori

ent

 

or

 

relocate

 

the

 

receiving

 

antenna

 

(2)

 

Increase

 

the

 

separa on

 

between

 

the

 

equipment

 

and

 

receiver

 

(3)

 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

di

erent

 

from

 

that

  

to

 

which

 

the

 

receiver

 

is

 

connected

 

(4)

 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

  

technician

 

for

 

help.

  

NEMA

 

TS

 

2

2003

 

v02.06

  

Sec ons

 

2.2.7.3—2.2.7.6

 

,

 

2.2.8.4

  

and

  

2.2.9

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

NEMA

 

TS

 

2

2003

 

environmental

 

requirements

 

as

 

are

 

applicable

 

for

 

this

 

device.

  

The

 

requirements

 

applicable

 

are

 

(1)

 

Opera ng

 

voltage

 

(2)

 

Opera ng

 

Frequency

 

(3)

 

Temperature

 

and

 

Humidity

 

(4)

 

Ambient

 

Temperature

 

(5)

 

Humidity

 

(6)

 

Vibra on

 

and

 

(7)

 

Shock.

  

Содержание 1RU8126MS

Страница 1: ...W ITSCOMMANDER COM Read this manual before using this product Failure to follow the instruc ons and safety precau ons in this manual can result in serious injury or death Keep this manual in a safe lo...

Страница 2: ...hern Manufacturing herea er referred to as EP shall not be held liable for any damage or injury involving its enclosures and or its remote power manager and monitoring system if used or operated in an...

Страница 3: ...fica ons 6 2 General Informa on Specifica ons 7 Features 8 3 Installa on Moun ng 9 Installa on 10 Set Up 11 4 User Interface Tabs Summary 18 Names and No fica ons 19 Scheduler 19 Unit Log 25 Configura...

Страница 4: ...g the capability to remotely control outlets to reboot equipment These features can reduce unnecessary trips to inspect or service the cabinet thereby saving money Southern Manufacturing s ITS Command...

Страница 5: ...the risk of serious injury or death and to ensure the con nued safe opera on of this product NOTE Notes provide addi onal informa on when comple ng a specific task or procedure Notes will be designat...

Страница 6: ...ar cular installa on If this equipment does cause harmful interference to radio or televi sion recep on which can be determined by turning the equipment o and on the user is en couraged to try to corr...

Страница 7: ...urrent 10 A Relay Connector 12 Posi on Screw Terminal 12 22 AWG Temperature Sensor Thermistor R 25 C 10k 1 4 1 feet 1 25m Humidity Sensor 26mV RH 3 RH Linear 3 3 V Supply Temperature Humidity Connecto...

Страница 8: ...tatus indicator Green labeled A through H 5 LCD Screen 6 Select Bu on 7 Ethernet Port ITEM DESCRIPTION Features 1 2 4 3 6 7 8 8 5 9 10 11 12 13 14 8 Adjustable rack moun ng ears 9 I O Expansion Port 1...

Страница 9: ...ket loca on 1 Remove retaining screws from unit body 2 Choose the loca on of the bracket by aligning the moun ng bracket holes to the unit body 3 Secure using retaining screws 4 Repeat for the other s...

Страница 10: ...the user interface Laptop PC etc 1 Connect an RJ45 patch cable to the ITS Commander Ethernet Port 2 Connect the other end of the RJ45 Patch cable to the network switch 3 User interface may be accessed...

Страница 11: ...serve as an ON OFF switch CAUTION Ensure input circuit breaker is in the OFF posi on before applying power to the unit CAUTION Do not remove the MALE end of the power cord in order to hardwire the un...

Страница 12: ...labeled A H indicate the ON OFF status of each outlet An illuminated LED means ON Relays 1 Connect desired equipment to the relay posi on using 12 22 AWG wire 2 Relay labels may be changed in the Name...

Страница 13: ...d NC contact closures may be changed in the Names and No fica ons tab 5 LEDs on the rear of the unit labeled Input 1 12 indicate the OPEN CLOSED status of each input An illuminated LED means a CLOSED...

Страница 14: ...ture probe to the following pins Pin 4 TEMP Pin 5 GND 2 Temperature threshold levels may be changed in the Names and No fica ons tab Analog Input 1 Connect desired equipment to the analog posi on usin...

Страница 15: ...s bar h p 192 168 0 50 2 When first accessing the user interface log in to the unit using the default log in informa on 3 To configure the unit select the Configura on User name admin Password its Sys...

Страница 16: ...s may cause the unit to lose network connec vity If connec vity is lost hold down the front panel bu on to restore the unit to its default se ngs Network Email SMS 1 Enter the desired Email address in...

Страница 17: ...o 3 Read and Write Communi es as desired 2 Select No fica ons Enabled if no fica ons traps are desired 3 Enter the Receiver IP address 4 Enter the community name Click Save Configura on to save change...

Страница 18: ...ica ons tab Dry contact inputs are green when in a non Alarm status Default Alarm status is a closed contact Dry contact inputs will turn red when in an Alarm status as set in the Names and No fica on...

Страница 19: ...Will turn red when upper threshold is exceeded and blue when lower thresholds are exceeded Thresholds may be changed in the Names and No fica ons tab Analog 1 and Analog 2 voltages are displayed when...

Страница 20: ...an email no fica on all state changes Select SNMP to receive a trap no fica on all state changes Names and No fica ons Tab con nued Inputs Input Labels can be changed for each outlet max 30 character...

Страница 21: ...ap no fica on threshold limits Enter the desired voltage hysteresis default 1 volt Environmental Set Lower and Upper threshold limits Temperature units may be changed in the configura on tab Select Em...

Страница 22: ...N Ac on taken during the event NEXT Lets the user know a er changes have been saved when the next scheduled ac on is to take place for that event Daily Recurring NAME Event label can be changed max 30...

Страница 23: ...Lets the user know a er changes have been saved when the next scheduled ac on is to take place for that event Weekly Recurring NAME Event label can be changed max 30 characters TIME Time for the desi...

Страница 24: ...o a ected ACTION Ac on taken during the event MONTHS Select months in which the event is to occur NEXT Lets the user know a er changes have been saved when the next scheduled ac on is to take place fo...

Страница 25: ...log entries are displayed Click NEXT to navigate trough further entries To download the log file Select the records start and stop date Unit Log NOTE An asterisk indicates a change in the status since...

Страница 26: ...ca on The configura on file may also be uploaded into a unit Items covered in the configura on file Schedule Names and No fica ons Configura on File To upload a configura on file 1 Click Choose File 2...

Страница 27: ...visit www ITSCOMMANDER com for firmware updates The Firmware tab allows the user to change the download firmware updates Please visit www ITSCOMMANDER com to download firmware updates for this unit To...

Страница 28: ...22 ITS COMMANDER Model 1RU8126MS Page 28 Technical Assistance NOTE Please visit www ITSCOMMANDER com for Q A and Technical Assistance You may also email us at contactus ITSCOMMANDER com or phone us a...

Страница 29: ...GE CAUSED BY IMPROPER INSTALLATION DAMAGE CAUSED BY A THE INSTALLER DAMAGE CAUSED BY ROADWAY TRAFFIC ACTS OF VANDALISM ACTS OF GOD NORMAL WEAR AND TEAR MODIFICATIONS OR ALTERATION OTHER THAN NORMAL MA...

Отзывы: