ZERO SEQUENCE I TRAPPED
Trapped
Vectoriel sum of I vectors greater than prog.threshold
during a time greater than duration threshold
CLOCK LOSS
Self-healing
Incoherence of internal clock after power cut
(
see note 5 below
)
EXTERNAL ALARM
Self-healing
Active signal on control input alarm detected
CURRENT REVERSAL (PHASE 1)
Self-healing
Change of direction of current flow on phase 1
CURRENT REVERSAL (PHASE 2)
Self-healing
Change of direction of current flow on phase 2
CURRENT REVERSAL (PHASE 3)
Self-healing
Change of direction of current flow on phase 3
TEMPERATURE
Self-healing
Meter temperature greater than threshold
VOLTAGE CUT (PHASE 1)
Self-healing
Voltage cut on phase 1 longer than threshold
VOLTAGE CUT (PHASE 2)
Self-healing
Voltage cut on phase 2 longer than threshold
VOLTAGE CUT (PHASE 3)
Self-healing
Voltage cut on phase 3 longer than threshold
VOLTAGE SAG (PHASE 1)
Self-healing
Voltage sag on phase 1 longer than threshold
VOLTAGE SAG (PHASE 2)
Self-healing
Voltage sag on phase 2 longer than threshold
VOLTAGE SAG (PHASE 3)
Self-healing
Voltage sag on phase 3 longer than threshold
VOLTAGE SWELL (PHASE 1)
Self-healing
Voltage swell on phase 1 longer than threshold
VOLTAGE SWELL (PHASE 2)
Self-healing
Voltage swell on phase 2 longer than threshold
VOLTAGE SWELL (PHASE 3)
Self-healing
Voltage swell on phase 3 longer than threshold
BATTERY
Trapped
Battery voltage level less than threshold
(
see note 5 below
)
MAGNET SENSOR
Trapped
External magnetic field detected by sensors
EXCESS DEMAND
Self-healing
Demand over threshold detected
CURRENT REVERSAL AGGREGATE
Trapped
Change of direction of current flow on phase 1 or
phase 2 or phase 3
MISSING APS
Self-healing
APS paramter configured with APS and APS voltage
not detected
Fatal alarm
Type
Description
INTERNAL RAM ERROR
Trapped Permanent checksum error in internal RAM
EXTERNAL RAM ERROR
Trapped Permanent checksum error in external RAM
INTERNAL PROGRAM MEMORY ERROR
Trapped Permanent checksum error in internal code
EXTERNAL PROGRAM MEMORY ERROR
Trapped Permanent checksum error in external code
Note
Alarm(s)
Comment
1
WATCHDOG ACTIVITY
NON VOLATILE MEMORY NON
FATAL ERROR
When these non-fatal alarms are detected, the meter uses the
previous 4 hours backup values.
It is recommended you remove/replace the meter, or at least erase
the fault with the support software and investigate the situation.