![ITRON SL7000 IEC7 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/itron/sl7000-iec7/sl7000-iec7_user-manual_2096057078.webp)
User Guide SL7000 IEC7
76
Item
Dimension
Description
A
230
Upper fixing point (1) to lower fixing points (centre to centre)
B
201
Upper fixing point (2) to lower fixing points (centre to centre)
C
150
Left to right lower fixing points (centre to centre)
D
252
Upper fixing point (1) centre to lower edge of meter body
E
4
Lower edge of meter body to lower edge of short terminal cover
E
58
Lower edge of meter body to lower edge of standard terminal cover
E
93
Lower edge of meter body to lower edge of long terminal cover
All dimensions are in millimetres.
9.5.
Auxiliary and communication wiring
Auxiliary wiring for Full IO Board
Terminal
Function
Terminal
Function
Terminal
Function
20
Control output 1
29
Pulse output 1
36
Pulse input 1
21
Control output 2
30
Pulse output 2
37
Pulse input 2
22
Control output 3
31
Pulse output 3
38
Pulse input 3
23
Control output 4
32
Pulse output 4
39
Pulse input 4
33
Pulse output 5
40
PI Common
25
CO Common
34
Pulse output 6
26
Control input 1
35
PO Common
27
Control input 2
28
CI Common
The control output and input terminal blocks accept cables up to 2.5mm².
The pulse output and input terminal blocks accept cables up to 1.5mm².
Auxiliary wiring for Light IO Board
Terminal
Function
Terminal
Function
Terminal
Function
22
Control output 1
33
Pulse output 1
38
Pulse input 1
23
Control output 2
34
Pulse output 2
39
Pulse input 2