Operation: C12.19 C1SD, C1ST, and C1SL Versions
CENTRON® Meter Technical Reference Guide
61
For meters with batteries, all logged events are retained through a power outage. For meters
without batteries, the Event Log is periodically written to non-volatile memory. Events that
occur just prior to a power outage may be lost depending on whether they were backed-up
or not.
The contents of the event log can be viewed using the meter programming software.
The following events may be configured for recording in the C12.19 C1SD/T/L register
Event Log:
Billing Schedule Expired
—billing schedule has expired and needs to be updated in
PC-PRO+ Advanced
Clear Billing Data
—billing data has been cleared upon initialization of the meter, or as
a secondary activity by authorized personnel
Configuration Error
—meter configuration was not successful
Demand Reset
—a demand reset occurred
DST Time Change
—DST adjustment forward or backward has occurred
Event Log Cleared
—Event Log was cleared by programming software
Full Scale Overflow
—Non-Fatal Error Codes for description
Load Profile Error
—Non-Fatal Error Codes for description
Logon Successful
—a user or option board logged on successfully to the meter
Low Battery
—Non-Fatal Error Codes for description
Meter Reprogrammed
—meter was initialized or reconfigured
Power Outage
—power was lost
Power Restored
—power was restored
Rate Change
—TOU rate change occurred
Register Self Read
—self read occurred
Reverse Power Flow
—Non-Fatal Error Codes for description
Reverse Power Flow Restored
—delivered power flow resumed after reverse flow
exceeded a configured threshold
Season Change
—TOU season change occurred
Security Fail
—logon with security code failed
Security Pass
—logon with security code succeeded
Test Mode Entered
—Test Mode or Alternate Test Mode was entered
Test Mode Exited
—Test Mode or Alternate Test Mode was exited
Time Changed
—a time adjustment forward or backward occurred
TOU Schedule Error
—Non-Fatal Error Codes for description
Security Codes
Register security can be provided with primary, secondary, and tertiary security codes that
prevent unauthorized communication with CENTRON products. A Primary security code
allows complete access to the meter. A Secondary security code allows full read access with
limited write access to perform an automatic demand reset and to access the Alternate and
Test modes. A tertiary security code allows read-only access. For more information about
security codes, refer to the PC-PRO+ documentation.
Содержание Centron
Страница 1: ...CENTRON Meter Technical Reference Guide Effective Date October 2006...
Страница 10: ...Table of Figures x CENTRON Meter Technical Reference Guide Notes...
Страница 20: ...General Information 10 CENTRON Meter Technical Reference Guide Notes...
Страница 50: ...Operation C1SC Version 40 CENTRON Meter Technical Reference Guide Notes...
Страница 96: ...Glossary of Terms 86 CENTRON Meter Technical Reference Guide Notes...
Страница 100: ...Index 90 CENTRON Meter Technical Reference Guide Notes...