LED and ERROR Indications 

LED 1 – Green (power) 

LED 2 – Red (error condition) 

 

Green

 

LED

Red

 

LED

, and Error Indication 

ERR Output 

(DIP-SW4 

setting) 

Status 

LED 1 

(Green) 

LED 2 

(Red) 

OFF 

ON 

Error 

Condition* 

Result 

Normal 

operation 

 

 

 

 

No power 

 

 

 

 

Supply power 

(24V DC) 

Fuse blown 

 

Flashes 

(6Hz) 

 

 

 

 

Current overload 

Card must be 

replaced 

Back EMF 

 

Flashes/off 

(6Hz) 

 

○○○○○○

 

 

 

Supply voltage 

>40V DC for 2s. or 

60V DC for 0.1s 

Motor stops 

Low voltage 

(<15V) 

 

Flashes 

(6Hz) 

 

 

 

 

15V DC 

(>1s or 

5x in 0.5s) 

Motor does not 

operate 

Thermal 

protection** 

 

 

 

 

Motor or PCB 

overheated 

Motor stops 1s 

after reaction 

Motor lock 

 

Flashes 

(1Hz) 

  

 

 

 

Motor does not 

turn for 4s 

Motor stops 

Motor not 

plugged in 

 

 

 

 

Motor does not 

operate 

 

*To reset an error condition:  Remove input signals; then reapply an input signal to either 

CN2-1 (RUN) or CN2-2 (DIR) 

 
**If thermal device recovery is set for automatic, the error will reset 1min after the 

temperature has reached operating range, and as long as no external input has been 
applied. 

 

Back EMF error 

If card detects back EMF over 40V DC for 2sec or 60V DC for 0.1sec the motor will stop running 
and go into dynamic brake condition to slow the product down.   
Automatic Recovery 

The roller will automatically restart 1sec after the voltage goes below 30V DC with a run 
signal active 

Manual Recovery

 

Can only be reset 1sec after the voltage goes below 30V DC 

To reset an error condition:  Remove input signals; then reapply an input signal to either 
CN2-1 (RUN) or CN2-2 (DIR) 

 
 
 
 

Содержание Power Moller 24 CBM-105FN

Страница 1: ...f motor lock last for 4 seconds or thermal overload error lasts for 1 second or more Two 2 LEDs red green to identify the type of error and power Back EMF error for overspeeding protection Pulse signa...

Страница 2: ...ize 28 14AWG CN3 9 PIN connector MOTOR Male Connector on Card JST S9B XH A 9P Female Connector for Wiring JST XHP 9 PIN Description 1 GND Grey 2 12V DC Blue 3 Motor phase U Red 4 Motor phase V White 5...

Страница 3: ...output ERR 5 0V output PLS Wire size 28 20AWG Control Wiring Power to CN1 24V DC remains ON control motor through CN2 Press down spring clamp in connector with a small screwdriver Insert leads in prop...

Страница 4: ...24V 18V or greater for PNP Output Error and Motor Pulse signals Open collector 24V 25mA or less NPN PNP selectable for Error only Servo brake mode 0 2s delay between stop signal and servo brake reacti...

Страница 5: ...F 6 Error output FP type PNP NPN ON External direction signal only If a direction change signal should occur while the motor is running the motor will first stop for 0 5s Then the motor will start in...

Страница 6: ...or PCB overheated Motor stops 1s after reaction Motor lock Flashes 1Hz Motor does not turn for 4s Motor stops Motor not plugged in Motor does not operate To reset an error condition Remove input signa...

Страница 7: ...1 8 4 45 9 164 0 433 6 7 6 7 9 43 6 155 8 433 6 7 1 7 4 41 3 147 6 433 6 6 6 6 9 36 7 131 2 433 6 6 1 6 4 34 4 123 0 433 6 5 6 5 9 32 1 114 8 408 7 5 1 5 4 29 8 106 6 379 5 4 6 4 9 27 6 98 4 350 3 4 1...

Страница 8: ...ed by the applicable mounting bracket Proper mounting is required for tube rotation Check that the Power Moller s connector is properly inserted into the driver card In belt applications check the bel...

Страница 9: ...the correct connector see page 3 SW1 6 Check dip switch 1 6 is properly set for the output type you require see page 5 Error signal is discharged frequently Red LED2 If LED2 is illuminated or blinkin...

Страница 10: ...ating DC voltage is 24V 10 When running long distances from a DC power supply the voltage drop during motor operation across the power bus may be significant may drop below 15V If there is a large eno...

Страница 11: ...8811 Hanover Industrial Estates Fx 570 820 8838 Hanover Township PA 18706 rev13 0314 Revision History Revision Number Change 12 0508 Initial document 12 0723 Added trouble shooting section 12 0810 Cha...

Отзывы: