SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

 

Page 3 of 11 

 

 

www.itohdenki.com

 

ITOH DENKI, USA, INC. 

[email protected]

 

135 Stewart Road 

Ph:  570.820.8811 

Hanover Industrial Estates 

Fx:  570.820.8838 

Hanover Township, PA  18706 

rev13-0314 

SPECIFICATIONS 

Connections 

CN2 

5 PIN connector 

CONTROL 

Male Connector on Card 

WAGO #733-365 

Female Connector for Wiring 

WAGO #733-105 

PIN 

Description 

+24V DC or 0V input (RUN) 

+24V DC or 0V input (DIR) 

0 ~ +10V DC input (V-IN) 

+24V DC or 0V output (ERR) 

0V output (PLS) 

Wire size: 

28~20AWG 

 

Control Wiring 

 
Power to CN1 (24V DC) remains ON, control motor through CN2 

 

 

Press down spring clamp in connector with a 
small screwdriver. 
 
Insert leads in proper order. 
 
Lead should be stripped approx: 0.31~0.35” 
 
 

 

WAGO connector 
(included) must be 
inserted and/or pulled 
out carefully, so as not to 
damage other parts. 

 

 

NPN / PNP inputs 

The card(s) are ordered with the inputs preset from the factory – ALL NPN or ALL PNP.  The 
model designation will show the factory preset. 

 

CBM-103FN – NPN input type (Default) 

 

CBM-103FP – PNP input type 

Note – the output can be manually switched in the field by DIP switch SW1-6 – Output signal 
type for both CN2-4  

 
 

Содержание Power Moller 24 CBM-105FN

Страница 1: ...f motor lock last for 4 seconds or thermal overload error lasts for 1 second or more Two 2 LEDs red green to identify the type of error and power Back EMF error for overspeeding protection Pulse signa...

Страница 2: ...ize 28 14AWG CN3 9 PIN connector MOTOR Male Connector on Card JST S9B XH A 9P Female Connector for Wiring JST XHP 9 PIN Description 1 GND Grey 2 12V DC Blue 3 Motor phase U Red 4 Motor phase V White 5...

Страница 3: ...output ERR 5 0V output PLS Wire size 28 20AWG Control Wiring Power to CN1 24V DC remains ON control motor through CN2 Press down spring clamp in connector with a small screwdriver Insert leads in prop...

Страница 4: ...24V 18V or greater for PNP Output Error and Motor Pulse signals Open collector 24V 25mA or less NPN PNP selectable for Error only Servo brake mode 0 2s delay between stop signal and servo brake reacti...

Страница 5: ...F 6 Error output FP type PNP NPN ON External direction signal only If a direction change signal should occur while the motor is running the motor will first stop for 0 5s Then the motor will start in...

Страница 6: ...or PCB overheated Motor stops 1s after reaction Motor lock Flashes 1Hz Motor does not turn for 4s Motor stops Motor not plugged in Motor does not operate To reset an error condition Remove input signa...

Страница 7: ...1 8 4 45 9 164 0 433 6 7 6 7 9 43 6 155 8 433 6 7 1 7 4 41 3 147 6 433 6 6 6 6 9 36 7 131 2 433 6 6 1 6 4 34 4 123 0 433 6 5 6 5 9 32 1 114 8 408 7 5 1 5 4 29 8 106 6 379 5 4 6 4 9 27 6 98 4 350 3 4 1...

Страница 8: ...ed by the applicable mounting bracket Proper mounting is required for tube rotation Check that the Power Moller s connector is properly inserted into the driver card In belt applications check the bel...

Страница 9: ...the correct connector see page 3 SW1 6 Check dip switch 1 6 is properly set for the output type you require see page 5 Error signal is discharged frequently Red LED2 If LED2 is illuminated or blinkin...

Страница 10: ...ating DC voltage is 24V 10 When running long distances from a DC power supply the voltage drop during motor operation across the power bus may be significant may drop below 15V If there is a large eno...

Страница 11: ...8811 Hanover Industrial Estates Fx 570 820 8838 Hanover Township PA 18706 rev13 0314 Revision History Revision Number Change 12 0508 Initial document 12 0723 Added trouble shooting section 12 0810 Cha...

Отзывы: