HMP45 OPERATOR’S MANUAL
8
www.holemaker.com
2.2 Installing and uninstalling an annular cutter
Annular cutter installation and uninstallation should be carried out when the machine is
turned off and disconnected from the air supply!
Installing the annular cutter:
1. Raise the drive and the slide (2) up using the feed handles (3);
2. Raise the guard (1) to the maximum height in order to attain access to the arbor (4) grub
screws (5);
3. Insert the appropriate type of pilot (6) into the annular cutter (7);
4. Position the annular cutter (7) with the cutter facing up, so that the flat sides of the milling
cutter are found facing the grub screws (5)
5. Put the annular cutter (7) into the arbor socket (4);
6. Tighten the grub screws securely (5), locking onto the flat sections of the annular cutter.
Uninstalling the annular cutter:
1. Raise the drive and the slide (2) up using the feed handles (3);
2. Raise the guard (1) to the maximum height in order to attain access to the arbor (4) grub
screws (5).
3. Loosen the grub screws (5);
4. Remove the annular cutter (7) and the pilot pin (6) from the arbor socket (4).
1
3
2
4
5
6
7