Installation

Figure 3.

Wall Mounting Hole Locations

To Mount the Module in an Advent Cabinet

1.

Remove AC panel power and disconnect the backup 
battery(s).

2.

Remove the module cover and set it aside (Figure 2).

3.

Turn the module upside down and line up the holes on 
the back-plate at the desired location (Figure 4).

4.

Secure the back-plate to the cabinet using three 1/4 -
inch #6-32 self-tapping screws (not included).

Figure 4.

Mounting the Module in an Advent Cabinet

To Mount the Module in a Concord

 

Cabinet

1.

Remove AC panel power and disconnect the backup 
battery.

2.

Remove and discard the module cover (Figure 2).

3.

Insert a support standoff shown in Figure 5 (supplied 
with panel) into the panel circuit board.

Figure 5.

Support Standoff

4.

Slide the module back-plate onto the two clips located 
on the top-left corner or center of the cabinet 
(Figure 6).

 œÌi

The two mounting clips in the top-right corner of the 
cabinet are designated for a receiver module, but if a 
receiver module is not being used, the mounting clips 
may be used for the 8 Zone Input Module.

5.

Push the lower-right corner of the module onto the sup-
port standoff (see detail in Figure 6).

6.

Gently press the module up and onto the cabinet side 
tab. 

Figure 6.

Mounting the Module in a Concord Cabinet

9712G02A.DSF

MOUNTING HOLES

REED SWITCH

HOLDER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

MAGNET

CLIP

9712G11A.DSF

PANEL CABINET

(COVER NOT SHOWN)

MOUNTED MODULE

ROOM FOR 3RD

MODULE

MOUNT WITH 

SELF TAPPING

SCREWS

SUPPORT STANDOFF

8573g64A.DSF

PANEL 

END

MODULE

END

9712G08A.DSF

USABLE MOUNTING

CLIPS (6)

MOUNTED

MODULE

PANEL CABINET

(COVER NOT SHOWN)

DETAIL

SUPPORT STANDOFF

(Included with Concord 

panel accessory package)

SIDE TAB

Содержание 60-774 - Security SuperBus 2000 8-Zone Input Module

Страница 1: ...l is powered up the panel automatically reads the unique SuperBus 2000 device ID number and assigns a unit number to the module This elim inates manually setting DIP switches and the chance of identical unit number conflicts SuperBus 2000 Panels R Advent R Concord software versions 2 0 and later SuperBus panels communicate with SuperBus 2000 mod ules but require the module unit number to first be ...

Страница 2: ...r cover tamper R 1 4 inch 6 32 self tapping screws not included for Advent cabinet mounting R Support standoff included with Concord cabinet Installation The module can be mounted R On a wall R Inside an Advent cabinet R Inside a Concord cabinet R Inside a SuperBus module cabinet 60 698 Refer to the cabinet Installation Instructions for installation procedures Ìi For UltraGard installations the mo...

Страница 3: ... the module back plate onto the two clips located on the top left corner or center of the cabinet Figure 6 Ìi The two mounting clips in the top right corner of the cabinet are designated for a receiver module but if a receiver module is not being used the mounting clips may be used for the 8 Zone Input Module 5 Push the lower right corner of the module onto the sup port standoff see detail in Figu...

Страница 4: ...e installations 1 Figure 8 shows an example of how to connect up to eight normally closed N C or normally open N O intrusion circuits to the module Figure 8 Connecting N C and N O Intrusion Circuits to the Module Table 4 SuperBus Module Panel Wiring Module Terminals Advent Ultra Gard Concord 13 12VDC Red 12 4 14 BUS A Green 13 5 15 BUS B White 14 6 16 GND Black 15 3 9712G03A DSF 1 2 3 4 5 6 7 8 9 ...

Страница 5: ... Concord software versions 1 0 1 6 and UltraGard Panels Locate the DIP switches on the module circuit board Fig ure 1 and set switch 1 to M on for manual Figure 10 Set the remaining switches for the desired unit number 1 Do not change DIP switch settings once the panel is powered up UNIT NUMBER 0 7 for UltraGard UNIT NUMBER 0 15 for Concord Figure 10 Module Unit Number DIP Switch Settings Non Supe...

Страница 6: ...add SuperBus devices All installed devices are automatically added learned into panel memory when Devices Added is indicated 7 Press twice to return to the Main Menu 8 Both the green and red LEDs turn on for one second The green POWER LED will remain on and the red BUS LED should flash to indicate successful commu nication with the panel Ìi If the green POWER LED is not on or the red BUS LED does ...

Страница 7: ...Mutual applied for MEA New York City Material Equipment Acceptance applied for DOD Sensitive Compartment Information Fac applied for ULC Canada Commercial Fire Burglary Warning applied for Ìi See specific panel Installation Instructions for complete UL installation requirements for the system you are installing Table 6 Troubleshooting Problem Action Solution The green POWER LED stays off 1 Check f...

Страница 8: ...f the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will not occur in a particular inst...

Отзывы: