Power Up and Bus Communication

Power Up and 
Bus Communication

On Concord and Advent Panels

This section describes how to power up the panel and mod-
ule for both new and existing installations.

New Installations

1.

Verify that all wiring between the panel and module is 
correct.

2.

Connect the panel backup battery(s) and restore panel 
AC power. Alphanumeric touchpad displays should 
come on.

3.

Both the green and red LEDs will turn on for one sec-
ond. The green POWER LED will remain on and the 
red BUS LED should flash to indicate successful com-
munication with the panel.

 œÌi

If the green POWER LED is not on or the red BUS 
LED does not flash, remove AC panel power, discon-
nect the backup battery(s), and see Table 6 “Trouble-
shooting.”

Existing Installations

Concord Panels– Same as new installation.

Advent Panels–

1.

Verify that all wiring between the panel and module is 
correct.

2.

Connect the panel backup battery(s) and restore panel 
AC power. Alphanumeric touchpad displays should 
come on.

3.

Press 8 for System Menu.

4.

Press 0 for Program Menu.

5.

Enter your Install Code (default 0123).

6.

Enter Item Number 48001 to add SuperBus devices. 
All installed devices are automatically added (learned) 
into panel memory when Devices Added is indicated.

7.

Press * twice to return to the Main Menu.

8.

Both the green and red LEDs turn on for one second. 
The green POWER LED will remain on and the red 
BUS LED should flash to indicate successful commu-
nication with the panel.

 œÌi

If the green POWER LED is not on or the red BUS 
LED does not flash, remove AC panel power, discon-
nect the backup battery(s), and see Table 6 “Trouble-
shooting.”

On UltraGard Panels

1.

Verify that all wiring between the panel and module is 
correct.

2.

Verify nonconflicting bus device unit number settings. 

3.

Connect the panel backup battery and restore panel AC 
power.

4.

Turn on the panel AC power.

5.

Set the UltraGard panel RUN/PROGRAM switch to 
PROGRAM.

If the alphanumeric touchpad displays 1-OFF and the 1 
is flashing, you must enter the 4-digit installer code to 
place the panel into program mode.

Alphanumeric touchpads should display PROGRAM 
MODE
 and the red BUS LED on the module should be 
flashing continuously, indicating successful communi-
cation with the panel.

 œÌi

If the green POWER LED is not on or the red BUS 
LED does not flash, set the RUN/PROGRAM switch 
(UltraGard) to RUN, remove AC panel power, discon-
nect the backup battery, and see Table 6 “Trouble-
shooting.”

Содержание 60-774 - Security SuperBus 2000 8-Zone Input Module

Страница 1: ...l is powered up the panel automatically reads the unique SuperBus 2000 device ID number and assigns a unit number to the module This elim inates manually setting DIP switches and the chance of identical unit number conflicts SuperBus 2000 Panels R Advent R Concord software versions 2 0 and later SuperBus panels communicate with SuperBus 2000 mod ules but require the module unit number to first be ...

Страница 2: ...r cover tamper R 1 4 inch 6 32 self tapping screws not included for Advent cabinet mounting R Support standoff included with Concord cabinet Installation The module can be mounted R On a wall R Inside an Advent cabinet R Inside a Concord cabinet R Inside a SuperBus module cabinet 60 698 Refer to the cabinet Installation Instructions for installation procedures Ìi For UltraGard installations the mo...

Страница 3: ... the module back plate onto the two clips located on the top left corner or center of the cabinet Figure 6 Ìi The two mounting clips in the top right corner of the cabinet are designated for a receiver module but if a receiver module is not being used the mounting clips may be used for the 8 Zone Input Module 5 Push the lower right corner of the module onto the sup port standoff see detail in Figu...

Страница 4: ...e installations 1 Figure 8 shows an example of how to connect up to eight normally closed N C or normally open N O intrusion circuits to the module Figure 8 Connecting N C and N O Intrusion Circuits to the Module Table 4 SuperBus Module Panel Wiring Module Terminals Advent Ultra Gard Concord 13 12VDC Red 12 4 14 BUS A Green 13 5 15 BUS B White 14 6 16 GND Black 15 3 9712G03A DSF 1 2 3 4 5 6 7 8 9 ...

Страница 5: ... Concord software versions 1 0 1 6 and UltraGard Panels Locate the DIP switches on the module circuit board Fig ure 1 and set switch 1 to M on for manual Figure 10 Set the remaining switches for the desired unit number 1 Do not change DIP switch settings once the panel is powered up UNIT NUMBER 0 7 for UltraGard UNIT NUMBER 0 15 for Concord Figure 10 Module Unit Number DIP Switch Settings Non Supe...

Страница 6: ...add SuperBus devices All installed devices are automatically added learned into panel memory when Devices Added is indicated 7 Press twice to return to the Main Menu 8 Both the green and red LEDs turn on for one second The green POWER LED will remain on and the red BUS LED should flash to indicate successful commu nication with the panel Ìi If the green POWER LED is not on or the red BUS LED does ...

Страница 7: ...Mutual applied for MEA New York City Material Equipment Acceptance applied for DOD Sensitive Compartment Information Fac applied for ULC Canada Commercial Fire Burglary Warning applied for Ìi See specific panel Installation Instructions for complete UL installation requirements for the system you are installing Table 6 Troubleshooting Problem Action Solution The green POWER LED stays off 1 Check f...

Страница 8: ...f the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will not occur in a particular inst...

Отзывы: