ITI 60-774 - Security SuperBus 2000 8-Zone Input Module Скачать руководство пользователя страница 8

8

Notices

Notices

FCC Part 15 Information to the User

Changes or modifications not expressly approved by Interactive Technologies, 
Inc. can void the user’s authority to operate the equipment.

FCC Part 15 Class A

This equipment has been tested and found to comply with the limits for a class A 
digital device, pursuant to part 15 of the FCC rules.  These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment.  

This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications.  Operation of this equipment in a residential 
area is likely to cause harmful interference in which case users will be required to 
correct the interference at their own expense.

FCC Part 15 Class B

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against interference in a residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interfer-
ence to radio communications. However, there is no guarantee that interference 
will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is encour-
aged to try to correct the interference by one or more of the following measures:

R

Reorient or relocate the receiving antenna.

R

Increase the separation between the equipment and receiver.

R

Connect the affected equipment and the panel receiver to separate outlets, 
on different branch circuits.

R

Consult the dealer or an experienced radio/TV technician for help.

©2000 Interlogix

, Inc. ITI, Advent, UltraGard, and SuperBus are regis-

tered trademarks of Interlogix, Inc. Interlogix and Concord are trademarks 
of Interlogix, Inc.

www.itii.com

T:  651/777-2690
F:  651/779-4890

2266 Second Street North
North Saint Paul, MN 55109-2900

1-800-777-1415

Содержание 60-774 - Security SuperBus 2000 8-Zone Input Module

Страница 1: ...l is powered up the panel automatically reads the unique SuperBus 2000 device ID number and assigns a unit number to the module This elim inates manually setting DIP switches and the chance of identical unit number conflicts SuperBus 2000 Panels R Advent R Concord software versions 2 0 and later SuperBus panels communicate with SuperBus 2000 mod ules but require the module unit number to first be ...

Страница 2: ...r cover tamper R 1 4 inch 6 32 self tapping screws not included for Advent cabinet mounting R Support standoff included with Concord cabinet Installation The module can be mounted R On a wall R Inside an Advent cabinet R Inside a Concord cabinet R Inside a SuperBus module cabinet 60 698 Refer to the cabinet Installation Instructions for installation procedures Ìi For UltraGard installations the mo...

Страница 3: ... the module back plate onto the two clips located on the top left corner or center of the cabinet Figure 6 Ìi The two mounting clips in the top right corner of the cabinet are designated for a receiver module but if a receiver module is not being used the mounting clips may be used for the 8 Zone Input Module 5 Push the lower right corner of the module onto the sup port standoff see detail in Figu...

Страница 4: ...e installations 1 Figure 8 shows an example of how to connect up to eight normally closed N C or normally open N O intrusion circuits to the module Figure 8 Connecting N C and N O Intrusion Circuits to the Module Table 4 SuperBus Module Panel Wiring Module Terminals Advent Ultra Gard Concord 13 12VDC Red 12 4 14 BUS A Green 13 5 15 BUS B White 14 6 16 GND Black 15 3 9712G03A DSF 1 2 3 4 5 6 7 8 9 ...

Страница 5: ... Concord software versions 1 0 1 6 and UltraGard Panels Locate the DIP switches on the module circuit board Fig ure 1 and set switch 1 to M on for manual Figure 10 Set the remaining switches for the desired unit number 1 Do not change DIP switch settings once the panel is powered up UNIT NUMBER 0 7 for UltraGard UNIT NUMBER 0 15 for Concord Figure 10 Module Unit Number DIP Switch Settings Non Supe...

Страница 6: ...add SuperBus devices All installed devices are automatically added learned into panel memory when Devices Added is indicated 7 Press twice to return to the Main Menu 8 Both the green and red LEDs turn on for one second The green POWER LED will remain on and the red BUS LED should flash to indicate successful commu nication with the panel Ìi If the green POWER LED is not on or the red BUS LED does ...

Страница 7: ...Mutual applied for MEA New York City Material Equipment Acceptance applied for DOD Sensitive Compartment Information Fac applied for ULC Canada Commercial Fire Burglary Warning applied for Ìi See specific panel Installation Instructions for complete UL installation requirements for the system you are installing Table 6 Troubleshooting Problem Action Solution The green POWER LED stays off 1 Check f...

Страница 8: ...f the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will not occur in a particular inst...

Отзывы: