Electrical installation
Page 78
8.3.3
Pin assignment [X9]
Table 33:
Pin assignment [X9]
Pin no.
Name
Value
Specification
1
L1
230 ... 480 VAC [± 10%],
50 ... 60 Hz
Mains phase 1
2
L2
Mains phase 2
3
L3
Mains phase 3
4
ZK+
< 700 VDC
Pos. DC bus circuit voltage
5
ZK-
GND_ZK
Neg. DC bus circuit voltage
6
BR-EXT
< 800 VDC
Connection of the external braking resistor
8
BR-CH
< 800 VDC
Brake chopper, connection for the internal braking
resistor against BR-INT or of the external braking
resistor against ZK+
7
BR-INT
< 800 VDC
Connection of the internal braking resistor
(bridge to BR-CH when using the internal resistor)
9
PE
PE
Connection of the protective earth (ground)
conductor of the mains power supply
10
+24 V
24 VDC [± 20%], 1 A
*)
Supply voltage for the control module and holding
brake
11
GND24V
GND (0 VDC)
Supply voltage reference potential
*)
plus the current consumption of a holding brake and I/Os (if included)
8.3.4
Cable type and configuration [X9]
The cable names that are stated refer to cables made by Lapp. They have proved to be reliable and are successfully used in
many applications. However, it is also possible to use comparable cables from other manufacturers, for example Lütze or
Helukabel.
For the 400 V supply:
LAPP KABEL ÖLFLEX CLASSIC 110; 4 x 1.5 mm²
Содержание C 3-Series
Страница 12: ...Page 12 Figure 33 Servo positioning controller with an integrated technology module 160 ...
Страница 70: ...Mechanical installation Page 70 Figure 8 item Servo Positioning Controller C 3 Series installation space ...
Страница 71: ...Mechanical installation Page 71 7 2 Device view Figure 9 item Servo Positioning Controller C 3 10 front view ...
Страница 76: ...Electrical installation Page 76 Figure 14 Complete set up of the item C 3 Series with a motor and PC ...