Electrical installation
Page 80
8.4
Connector: motor [X6]
8.4.1
Configuration on the device [X6]
PHOENIX Power-COMBICON
PC 4/9-G-7.62 BK
8.4.2
Mating connector [X6]
PHOENIX Power-COMBICON
PC 4 HV/9-ST-7.62 BK
8.4.3
Pin assignment [X6]
Table 35:
Pin assignment [X6]
Pin no.
Name
Value
Specification
1
BR-
0 V brake
Holding brake (motor), signal level depending on
the switching state, high-side/low-side switch
2
BR+
24 V brake
3
PE
PE
Inner shield connection (holding brake +
temperature sensor)
4
MT-
GND
Motor temperature sensor
1)
, normally closed
contact, normally open contact, PTC, NTC, KTY
5
MT+
+ 3.3 V/5 mA
6
PE
PE
Protective earth (ground) conductor of the motor
7
W
0 ... 360 V
RMS
0 ... 5 A
RMS
0 ... 10 A
RMS
0 ... 1000 Hz
Connection of the three motor phases
8
V
9
U
1)
Please refer to
chapter 9 Additional requirements to be fulfilled by the servo positioning controllers for UL approval
page 113.
In addition, the outer cable shield of the motor cable must be connected to the mounting plate of the
controller over a large contact area with the aid of shield terminal SK14.
Содержание C 3-Series
Страница 12: ...Page 12 Figure 33 Servo positioning controller with an integrated technology module 160 ...
Страница 70: ...Mechanical installation Page 70 Figure 8 item Servo Positioning Controller C 3 Series installation space ...
Страница 71: ...Mechanical installation Page 71 7 2 Device view Figure 9 item Servo Positioning Controller C 3 10 front view ...
Страница 76: ...Electrical installation Page 76 Figure 14 Complete set up of the item C 3 Series with a motor and PC ...