Maintenance
PROBLEM
CAUSE
SOLUTION
Motor runs but pump
does not inject or
dosing is lower than
nominal
- Pump not primed
- Prime the pump by opening the priming
valve or filling the head with the liquid to
be injected
- Dirty or damaged suction or
delivery valve
- Clean or change valves
- Dirty suction filter
- Clean filter
- Air enters the suction pipe
- Check tightness of connection points
- Cavitation in suction
- Increase pipe diameter.
- Reduce the suction pipe length.
- Reduce speed by using a variator.
- Use a less viscous liquid.
Pump drips liquid
from bottom orifice of
cylinder
- Damaged diaphragm
- Change diaphragm