Operation
5.1 OPERATING MODES
5.1.1 Manual mode
This mode allows manual adjustment of the dosing flow rate.
5.1.2 Proportional mode
This mode allows dosing to be proportional to a pulsed input. Use X:Y mode to establish a ratio of input
pulses (X) to pump cycles (Y). Use the %/ppm mode for proportional dosing.
Proportional mode settings
5.1.2.1 X:Y pulses
The pump will cycle Y times after receiving X input pulses. The pump speed can be adjusted manually.
%
l / h
0 0 0
0 0 0
MODE
MODE:
Manual
Proportional
Analog
Batch
l / h
M
o
%
0 0 0
0 0 0
off
l
l / h
M
%
3 1
4 4
ENT
ENT
ENT
Increase/decrease flow
Start/stop the pump
The pump will start if the Remote Activation input is
activated.
Proportional to a pulse input from a flowmeter
1. X:Y for low frequency pulses (0,005 - 30 Hz)
2. %/ppm for high frequency flowmeters (1 - 300 Hz)
%
l / h
0 0 0
0 0 0
MODE
MODE: Manual
Analog
Batch
Proportional
l / h
10
m3/h
o
%
0 0 0
0 0 0
Proportional
% / PPM Flowmet.
X:Y Pulse
ENT
ENT
0001
:
Q = 025
%
M = 005 pulses
0001
PROPORTIONAL X:Y
25.0
25.0
25.0
25.0
7.75
Select the number of input pulses
Change by pressing
and confirm by pressing
ENT