5.3 ALARMS
In the event of an alarm, the corresponding icon will flash on the main screen. If the cause of the alarm
disappears the icon will remain steady. To erase the alarm icon, it is necessary to stop and start the pump
using the “ENT” key. The security time is 5 seconds before any alarm is activated.
5.3.1 Level alarm 1
Low level pre-warning according to Level 1 input. Automatic reset (see connection 4.2).
5.3.2 Level alarm 2
Low level alarm according to Level 2 input. Automatic reset (see connection 4.2).
x3
x3
ENT
ENT
ENT
LEVEL 1 PRE EMPTY
Alarm
Relay out OFF
Stop pump
OFF
OFF
LEVEL 1 PRE EMPTY
Alarm ON
Level relay
Stop pump
OFF
OFF
LEVEL 1 PRE EMPTY
Alarm ON
Relay out
Stop pump
OFF
OFF
LEVEL 1 PRE EMPTY
Alarm ON
Level relay
Stop pump
OFF
OFF
LEVEL 1 PRE EMPTY
Alarm ON
Level relay ON
Stop pump
OFF
MENU ALARM
LEVEL 2
FLOW
LEAKAGE
PRESSURE
LEVEL 1
MENU ALARM
LEVEL 2
FLOW
LEAKAGE
PRESSURE
LEVEL 1
%
l / h
0 0 0
000
MODE
25.0
%
l / h
0 0 0
000
MODE
25.0
ENT
When replacing a component that
has reached the end of its useful
life, the cycle counter must be set
to zero by using the YES option.
Diaphragm change
- 518.4k Strokes
Chenged?
YES
NO
MAINTENANCE
VALVES
DIAPHRAGM
BELLOW
!
Activate or deactivate, stop the pump when the alarm goes off, by
pressing
and validate by pressing
ENT
Activate or deactivate the Alarm Relay output, when the unit is in
alarm, by pressing
and confirm by pressing
ENT
Activate or deactivate the alarm by pressing
and
confirm by pressing
ENT